Ocp Status And Error Messages - Digital Equipment 7100R Series Service Maintenance Manual

Hide thumbs Also See for 7100R Series:
Table of Contents

Advertisement

OCP Status and Error Messages

Status
Normal OCP
Display
CPU ambient
CPU1 temp=xxxC
temperature
CPU2 temp=xxxC
CPU3 temp=xxxC
CPU4 temp=xxxC
Power supply
P/S1 OK
status
P/S2 OK
P/S3 OK
Fan status
Sys fans OK
CPU status
6000MPn
n = CPU number
OCP Error
Display
CPU1 over heat
CPU2 over heat
CPU3 over heat
CPU4 over heat
P/S1 fail
P/S2 fail
P/S3 fail
Sys fan 1 fail
Sys fan 2 fail
Sys fan 3 fail
Sys fan 4 fail
CPU1 fail
CPU2 fail
CPU3 fail
CPU4 fail
No CPU exists
Description of
Error Display/Action
Temperature of processor 1 is out of range.
Temperature of processor 2 is out of range.
Temperature of processor 3 is out of range.
Temperature of processor 4 is out of range.
Action: Verify fans are operational.
Action: Check that heat sink is correctly
attached to the processor chip.
Power supply 1 is not working.
Power supply 2 is not working.
Power supply 3 is not working.
Action: Replace any failed power supply.
Fan 1 is not working.
Fan 2 is not working.
Fan 3 is not working.
Fan 4 is not working.
Action: Replace any failed fan.
Internal defect of processor 1 or internal
temperature exceeds the upper limit.
Internal defect of processor 2 or internal
temperature exceeds the upper limit.
Internal defect of processor 3 or internal
temperature exceeds the upper limit.
Internal defect of processor 4 or internal
temperature exceeds the upper limit.
No processors are present in the server.
Action: Reboot server and check if the failed
processor is still malfunctioning during POST.
Troubleshooting
continued
4-15

Advertisement

Table of Contents
loading

Table of Contents