Kenmore 111.72695120 Service Manual page 16

Table of Contents

Advertisement

5. Flow Diagram
5-3. Refrigerant Flow and Lokring Point
FZ1
FZ2
H
C
A
B
ST1,ST2,ST3
D
Location
Compressor
Condenser
Filter-drier
Suction Line
Step Valve
Ref evaporator
IM evaporator
FZ evaporator
To avoid risk of electrical shock that can cause death or severe personal injury,
WARNING
!
disconnect unit from power before servicing unless tests require power.
F
"PIPE CONN A1
AS"(connected from
compressor discharge
pipe to condenser inlet
E
pipe) included in
Condenser Ass'y("PIPE
WICON AS")
Tag
Description
A
Process Stub
B
Discharge
C
Suction
D
Cond Inlet
E
Cond Outlet/Yoder Inlet
F
Inlet/Yoder Outlet
G
Drier Outlet/Step Valve Inlet
H
Cabinet Outlet/Pipe Suc Conn Inlet
ST1
ST2
Outlets To cap tubes
ST3
R1
Inlet
R2
Outlet
IM1
Inlet
IM2
Outlet
FZ1
Inlet
FZ2
Outlet
FD2
FD1
D
E
G
L13000654
L13000630
L13000654
Non-serviceable
L13000622
L13000622
L13000621
L13000588
L13005976
L13000931
L13000654
L13000654
L13000654
L13000654
L13000654
IM2
IM1
OD6mm
Filter-drier
Lokring
Part Number
8/6NRMS00
6/5NRMS00
8/6NRMS00
5/4NRMS00
5/4NRMS00
5/3.5NRMS00
6NKMS00
2.8/1.8NRMS00
4/1.8NRMS00
8/6NRMS00
8/6NRMS00
8/6NRMS00
8/6NRMS00
8/6NRMS00
Spec.
16 / 69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents