Reference Mark; Limit Switches - Renishaw QUANTiC RKLC40-S Installation Manual

Incremental linear encoder system
Hide thumbs Also See for QUANTiC RKLC40-S:
Table of Contents

Advertisement

Reference mark

Type
Customer selected IN-TRAC reference mark, directly embedded into the incremental track. Bi-directional position repeatability
L ≤ 100 mm Single reference mark at scale centre
L > 100 mm Reference marks at 50 mm spacing (first reference mark 50 mm from scale end)
Selection
Customer positioned selector magnet (A-9653-0143) for selecting desired IN-TRAC reference mark
Repeatability
Unit of resolution repeatability (bi-directional) across full system rated speed and temperature ranges

Limit switches

Type
Magnetic actuators: with dimple triggers Q limit, without dimple triggers P limit (see
Trigger point
The limit output is nominally asserted when the readhead limit switch sensor passes the limit magnet leading edge, but can trigger up to 3 mm before that edge
Mounting
Customer placed at desired locations
Repeatability
< 0.1 mm
'RKLC40-S scale installation drawing'
on page 12)
www.renishaw.com
35