Figure 9-14: Downstream shaft nut installation
Important
The shaft nut can only be reused up to five times. Replace as needed.
9.5

Electronics enclosure disassembly

WARNING
ELECTRONIC HAZARD
Power off the electronics after every use.
Servicing the turbine meter while powered may result in death or serious injury.
Important
Do not use a hammer to assemble the housing.
9.5.1
Disassemble the LME/RME - Standard enclosure
Procedure
1. Uninstall the security seal wire.
2. Uninstall the security wire.
3. Uninstall the security latch.
4. Uninstall the solid end cap.
5. Uninstall the wiring connections from the preamplifier.
6. Loosen and remove the socket screws from the plate bracket to the housing.
7. Loosen and remove the preamplifier socket screw to the bracket plate.
8. Loosen the grounding lugs and remove the cable.
9. Uninstall the conduit.