Prepare the turbine meter for use
SERIES 1500 LIQUID TURBINE METER
March 2019
Figure 4-7: Security seal wire
Follow the steps below to seal the electronics enclosure.
Procedure
1. Rotate the end cap clockwise, fully closing and compressing the end cap seal. Install
2. Install the security seal wire into and through one of the two holes in the end cap
3. Adjust the security wire, removing all slack and thread into the lead seal.
4. Cut the ends of the wire to remove any excess wire.
64
www.Daniel.com
68
the security latch using a 3mm Allen wrench.
and the housing. Choose holes that minimize counterclockwise rotation of the end
cap when the security wire is taut (maximum wire diameter 2.0 mm, .078 inch).
Daniel Series 1500 Liquid Turbine Meter, NPS 3-24