7. Install the downstream hanger assembly to the shaft.
8. Install the downstream shaft nut, simultaneously holding the upstream shaft nut to
84
www.Daniel.com
94
Figure 9-12: Downstream cone installation
Figure 9-13: Downstream hanger assembly installation
prevent the shaft from turning.
Daniel Series 1500 Liquid Turbine Meter, NPS 3-24
User manual