Specifications
Control card, 10 V DC output
Terminal number
Output voltage
Max. load
The 10 V DC supply is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control characteristics
Resolution of output frequency at 0–1000 Hz
System response time (terminals 18, 19, 27, 29, 32, 33)
Speed control range (open-loop)
Speed accuracy (open-loop)
All control characteristics are based on a 4-pole asynchronous motor.
Surroundings
Enclosure type D1h/D2h/D5h/D6h/D7h/D8h
Enclosure type D3h/D4h
Vibration test all enclosure types
Relative humidity
Aggressive environment (IEC 60068-2-43) H
Test method according to IEC 60068-2-43 H2S (10 days)
Ambient temperature (at 60 AVM switching mode)
- with derating
- with full output power of typical EFF2 motors (up to 90% output current)
- at full continuous FC output current
1)
For more information on derating see the Design Guide, section on Special Conditions.
Minimum ambient temperature during full-scale operation
Minimum ambient temperature at reduced performance
Temperature during storage/transport
Maximum altitude above sea level without derating
Maximum altitude above sea level with derating
1)
For more information on derating see the Design Guide, section on Special Conditions.
EMC standards, Emission
EMC standards, Immunity
See the Design Guide, section on Special Conditions.
Control card performance
Scan interval
Control card, USB Serial Communication
USB standard
USB plug
CAUTION
Connection to PC is carried out via a standard host/device USB cable.
The USB connection is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
The USB connection is not galvanically isolated from protection ground. Use only an isolated laptop/PC as the connection to
the USB connector on the adjustable frequency drive or an isolated USB cable/drive.
®
VLT
HVAC Drive D-Frame
Instruction Manual
5%–95% (IEC 721-3-3; Class 3K3 (non-condensing) during operation
S test
2
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
®
MG16D222 - VLT
is a registered Danfoss trademark
1:100 of synchronous speed
30–4,000 rpm: Maximum error of ±8 rpm
IP21/Type 1, IP54/Type12
-13°–149°/158° F [-25 to +65°/70°C]
EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EN 61800-3, EN 61000-6-1/2,
USB type B "device" plug
50
10.5 V ±0.5 V
25 mA
± 0.003 Hz
≤2 ms
IP20/Chassis
1.0 g
class Kd
1)
max. 131° F [55°C]
1)
max. 122° F [50°C]
1)
max. 113° F [45°C]
32° F [0°C]
14° F [-10°C]
10
3,300 ft [1,000 m]
10,000 ft [3,000 m]
5 ms
1.1 (Full speed)
10-7
10