9. TEChNICAL dATA

mains voltage KPS 3~50/60 hz
mains voltage KPS mVu 3~50/60 hz
Rated power
60 ed
80 % ed
100 % ed
Connection cable/fuse delayed
KPs
KPs mvu
Max. loadability 40 ˚C
60 % ed
80 % ed
100 % ed
Max. loadability 20 ˚C
100 % ed
welding current and voltage range
mma
mig
max. welding voltage 46 v / 300 a
Open circuit voltage
Open circuit power
Efficiency at nominal values
Power factor at nominal values
Storage temperature range
Operating temperature range
Temperature class
degree of protection
External dimensions
length
width
height
weight
Voltage supply for auxiliary devices
X 14, X 15
Voltage supply for cooling unit
© Kemppi oy
Kemppi WeldForce KpS3500, KpS4500, KpS5500, KpS3500mVU, KpS4500mVU, 5500KpSmVU / 0606 – 11
Kemppi weldForce
KPS 3500/
KPS 3500mVu
400 v -15 %...+20 %
400 v -15 %...+20 %
230 v -10 %...+10 %
-
15 kva
13,5 kva
4 x 6 s - 5 m / 25 a
4 x 6 s - 5 m / 35 a
-
350 a
320 a
320 a
10 a ... 320 a
12 v ... 37 v
approx. 65 v
< 75 W
approx. 85 %
approx. 0,93
-40 ... +60 ºC
-20 ... +40 ºC
h (180 ºC) / b (130 ºC) h (180 ºC) / b (130 ºC)
iP 23 C
690 mm
230 mm
520 mm, mvu 630 mm 520 mm, mvu 630 mm
37 kg/ mvu 45 kg
50 v dC
fuse 6,3 a delayed
1~, 400 v / 250 va
Kemppi weldForce
KPS4500/
KPS 4500mVu
400 v -15 %...+20 %
400 v -15 %...+20 %
230 v -10 %...+10 %
21,5 kva
20 kva
18,5 kva
4 x 6 s - 5 m /35 a
4 x 10 s - 5 m /50 a
450 a
420 a
380 a
400 a
10 a ... 420 a
12 v ... 39 v
46 v / 400 a
approx. 65 v
< 75 W
approx. 85 %
approx. 0,93
-40 ... +60 ºC
-20 ... +40 ºC
iP 23 C
690 mm
230 mm
41 kg/mvu 49 kg
50 v dC
fuse 6,3 a delayed
1~, 400 v / 250 va
Kemppi weldForce
KPS5500/
KPS 3500mVu
400 v -15 %...+20 %
400 v -15 %...+20 %
230 v -10 %...+10 %
28 kva
24,5 kva
21 kva
4 x 6 s - 5 m / 35 a
4 x 16 s - 5 m / 63 a
550 a
500 a
440 a
450 a
10 a ... 520 a
12 v ... 42 v
50 v / 500 a
approx. 65 v
< 75 W
approx. 85 %
approx. 0,93
-40 ... +60 ºC
-20 ... +40 ºC
h (180 ºC) / b (130 ºC)
iP 23 C
690 mm
230 mm
520 mm, mvu 630 mm
48 kg/mvu 56 kg
50 v dC
fuse 6,3 a delayed
1~, 400 v / 250 va