9. The engine oil pressure gauge (Figure 62) indicates
the oil pressure of the engine. Under normal operating
conditions this gauge should indicate approximately
44–94 psi.
ENGINE OIL PRESSURE
Figure 62. Oil Pressure Gauge
10. The coolant temperature gauge (Figure 63) indicates
the coolant temperature. Under normal operating
conditions, this gauge should indicate approximately
167°–194°F (75°–90°C).
WATER
Figure 63. Coolant Temperature Gauge
11. The engine tachometer (Figure 64) indicates the
speed of the engine while the generator is operating.
Under normal operating conditions, this gauge should
indicate approximately 1,000 rpm when the engine
speed switch is in the LOW position, and 1,800 rpm
when the engine speed switch is in the HIGH position.
120
60
0
Figure 64. Engine Tachometer
12. Press the Main Circuit Breaker ON switch (Figure 65).
Figure 65. Main Circuit Breaker ON Switch
DCA600SSV4F3 60 HZ GENERATOR • OPERATION MANUAL — REV. #2 (11/15/22) — PAGE 45
GENERATOR STARTUP PROCEDURE (MANUAL)
4
8
0
kg/cm2
TEMP
150
180
RPMX10
210
SPEED
ON
13. Verify that the Main Circuit Breaker ON lamp (Figure 66)
is lit (ON).
Figure 66. Main Circuit Breaker ON Lamp
14. Place the GFCI circuit breakers in the ON position
(Figure 67).
Figure 67. GFCI Circuit Breakers (On)
15. Verify that the generator's ammeter (Figure 68) reads
the anticipated amount of current with respect to the
load. The ammeter will only display a current reading
if a load is in use.
Figure 68. Ammeter (Load)
16. The generator will run until manually stopped or an
abnormal condition occurs.
ON

Advertisement