7. Close all engine enclosure doors (Figure 53).
CORRECT
Figure 53. Engine Enclosure Doors
STARTING (MANUAL)
1. Set the Battery switch (Figure 54) to the ON position.
Figure 54. Battery Switch (On)
2. Place the Engine Speed switch in the LOW position
(Figure 55).
Figure 55. Engine Speed Switch (Low)
3. Place the Auto Start/Stop switch in the MANUAL
position to start the engine (Figure 56). Once the
engine starts, let the engine run for 1–2 minutes. Listen
for any abnormal noises.
AUTO
OFF/RESET
Figure 56. Auto Start/Stop Switch (Manual)
4. Once the engine starts, let the engine run for
1–2 minutes. Listen for any abnormal noises. If any
abnormalities exist, shut down the engine and correct
the problem. If the engine is running smoothly, place
the engine speed switch (Figure 57) in the HIGH (up)
position.
Figure 57. Engine Speed Switch (High)
PAGE 44 — DCA600SSV4F3 60 HZ GENERATOR • OPERATION MANUAL — REV. #2 (11/15/22)
GENERATOR STARTUP PROCEDURE (MANUAL)
INCORRECT
LOW (DOWN)
MANUAL
HIGH (UP)
5. The frequency meter (Figure 58) displays the 60-cycle
output frequency in hertz.
Figure 58. Frequency Meter
6. The AC voltmeter (Figure 59) indicates the
phase-to-phase voltage of the generator's output
terminals.
Figure 59. AC Voltmeter
7. If the voltage is not within the specified tolerance,
use the voltage regulator (Figure 60) to increase or
decrease the desired voltage.
DECREASE
Figure 60. Voltage Regulator
8. The AC ammeter (Figure 61) will indicate zero amps
with no load applied. When a load is applied, the
ammeter will indicate the amount of current that the
load is drawing from the generator.
Figure 61. AC Ammeter (No Load)
60 Hz
120
INCREASE