Control And Operation Panel - MQ Power WHISPERWATT DCA600SSV4F3 Operation Manual

60hz generator (volvo penta twd1672ge diesel engine)
Table of Contents

Advertisement

1
2 3
50
180
150
25
75
140
120
220
60
PSI
°F
RPMX10
0
100
100
0
260
OIL PRESS
WATER TEMP
SPEED
18
50
12
24
ECU
%
VOLTS
Integrated Gauge Panel
0
30
0
100
½
½
EATS System
Malfunction
°F
°F
Emission Related
E
F
E
Malfunction
Refill DEF
Low
EATS Error
FUEL
DEF
Fuel
ECU
Series 800 Controller
Engine Started
Shutdown
Pre-Alarm
Alarm
Screen
Program
Option
Acknowledge
Change
Exit
20
19
18
21
The definitions below describe the controls and functions
of the control and operation panel (Figure 9).
1. Air Filter Alarm Lamp — This yellow LED turns on
when the air filter element is clogged. If the lamp turns
on during operation, clean or replace the element
immediately.
2. Pre-Alarm Lamp — This yellow LED turns on when
engine or generator failure occurs during operation.
Confirm the existing warning message displayed on
the engine-generator controller by pushing the Alarm
Acknowledge button. The lamp will turn off when all
warning messages have been confirmed.
3. Shutdown Lamp — This red LED turns on when the
unit shuts down due to engine failure.
4. Panel Light — For operation at night, the panel light
illuminates the control panel for ease of reading meters
and gauges. Make sure the panel light switch is in the
OFF position when the light is not in use.
5. Voltage Regulator — Allows ± 15% manual adjustment
of the generator's output voltage.
PAGE 22 — DCA600SSV4F3 60 HZ GENERATOR • OPERATION MANUAL — REV. #2 (11/15/22)
4
5
14
180
210
15
F
16
17
Figure 9. Control And Operation Panel

CONTROL AND OPERATION PANEL

6
10
9
OFF
ON
13
12
OFF
ON
11
8
6. Voltage Change-Over Board — Six jumper plates
that allow the generator to be configured for 3-phase,
240 or 480 VAC output. Located inside the control box.
7. Main Circuit Breaker — This 3-phase, 1600-amp,
main circuit breaker is provided to protect the
U, V, and W output terminal lugs from overload. Located
inside the control box.
8. Circuit Breaker ON Switch — Closes the main circuit
breaker contacts.
9. Circuit Breaker ON Lamp — Illuminates (red) when
the main circuit breaker contacts are closed.
10. Circuit Breaker OFF Lamp — Illuminates (green)
when the main circuit breaker contacts are open.
11. Circuit Breaker OFF Switch — Opens the main circuit
breaker contacts.