Upgrade SSD Firmware
You can use a USB flash drive to upgrade your SSD firmware.
Before You Start
Prepare a USB flash drive that contains the SSD firmware, and insert the USB flash drive to your
device USB interface.
Steps
1. Go to Storage → SSD Management .
2. Click Firmware Upgrade.
3. Select Device Name as the USB flash drive that contains the SSD firmware.
4. Select the SSD firmware.
5. Click Upgrade.

10.1.2 Manage Local HDD

Configure HDD Group
Multiple HDDs can be managed in groups. Video from specified channels can be recorded onto a
particular HDD group through HDD settings.
Steps
1. Go to Storage → Storage Mode .
2. Select Mode as Group.
3. Click Apply.
4. Go to Storage → Storage Device .
5. Select a HDD.
Figure 10-1 Storage Device
6. Click
to enter Local HDD Settings interface.