PCE Health and Fitness PCE-CT 80 Series User Manual page 27

Coating thickness gauge
Table of Contents

Advertisement

Available languages

Available languages

5.3.3
Statistics
When making a measurement in measure mode, the current mean
value, the maximum and the minimum values will be displayed below
the current reading. To view the complete statistics, press
the menu that is now displayed, go to "Browse Stat." by using the
keys and confirm with
the currently selected memory group. To view the statistics of the other
memory groups, change the memory group as described in chapter
4.3 and go back to the statistics function.
The meter creates individual statistics based on the saved readings of
each memory group. In the statistics, the number of readings, the mean value, the minimum and
maximum values as well as the standard deviation will be displayed. When the memory is full in
direct mode, the first reading will be deleted and the new reading will be saved. The statistics will
be updated accordingly. When the memory is full in general mode, no new readings will be saved
and the statistics will not be updated. If you delete the current reading or all readings of the group,
the statistics will update.
5.3.4
Limit settings
Each memory group has its own upper and lower limit value. When changing the memory group,
the limit values will be switched automatically. When a limit value is exceeded/fallen below, the
red LED on the left will flash. Moreover, a
exceeded or a
if the lower limit has been fallen below.
To enter the upper and lower limit value, follow these steps:
1.
Press
to enter the "Root" menu.
2.
Navigate to "Limit" with the
3.
Navigate to "Settings" with the
.
4.
Use the
and confirm with
5.
Set the limit value with
the procedure with
To enter the upper and lower limit value, follow these steps:
1.
Press
to enter the "Root" menu.
2.
Navigate to "Limit" with the
3.
Navigate to "Clear" with the
4.
A dialogue box opens. Confirm with
cancel
To enter or delete the limit values of other memory groups, change the group as described in
chapter 4.3 and follow the steps described above again.
. You can now see the statistical values of
keys and confirm with
keys to navigate to "High Limit" or "Low Limit"
.
and confirm with
.
keys and confirm with
keys and confirm with
the
procedure
© PCE Instruments
first. In
will be displayed when the upper limit has been
.
keys and confirm with
or cancel
.
.
to delete the readings of the memory group or
by
pressing
24
.

Advertisement

Table of Contents
loading

Table of Contents