PCE Health and Fitness PCE-TG1XX Manual

PCE Health and Fitness PCE-TG1XX Manual

Material thickness meter

Advertisement

Quick Links

PCE Americas Inc.
PCE Instruments UK Ltd.
711 Commerce Way
Units 12/13
Suite 8
Southpoint Business Park
Jupiter
Ensign way
FL-33458
Hampshire / Southampton
USA
United Kingdom, SO31 4RF
From outside US: +1
From outside UK: +44
Tel: (561) 320-9162
Tel: (0) 2380 98703 0
Fax: (561) 320-9176
Fax: (0) 2380 98703 9
info@pce-americas.com
info@pce-instruments.com
www.pce-instruments.com/english
www.pce-instruments.com
Manual
Material Thickness Meter PCE-TG1XX
Version 1.1
Date of creation: 29.06.2015
Date of last change: 28.06.2016

Advertisement

Table of Contents
loading

Summary of Contents for PCE Health and Fitness PCE-TG1XX

  • Page 1 From outside UK: +44 Tel: (561) 320-9162 Tel: (0) 2380 98703 0 Fax: (561) 320-9176 Fax: (0) 2380 98703 9 info@pce-americas.com info@pce-instruments.com www.pce-instruments.com/english www.pce-instruments.com Manual Material Thickness Meter PCE-TG1XX Version 1.1 Date of creation: 29.06.2015 Date of last change: 28.06.2016...
  • Page 2: Table Of Contents

    Manual Contents Introduction ......................3 Safety notes ......................3 Warning symbols ........................3 Safety precautions ........................3 Specifications ......................4 System description ....................5 Device ............................5 Keys ............................5 LC display ........................... 5 Instructions ......................6 Calibration........................... 6 How to set the sound velocity ..................... 6 Measurement ..........................
  • Page 3: Introduction

    For accurate measurement of wall thicknesses, the device uses ultrasonic technology. Different materials need different ultrasonic velocities. The PCE-TG1XX has been adjusted for five different sound velocities and for various materials at the factory. The sound velocity is freely adjustable and can thus be adapted to different materials.
  • Page 4: Specifications

    Manual Specifications Measurement range 0.8 … 225 mm TG 100 2.5 mm … 200 mm TG 110 1 … 30 mm TG 120 Possible materials ferrous and non-ferrous materials, steel, plastic, glass, gold and other homogeneous materials (without air pockets) Frequency standard 5 MHz Resolution...
  • Page 5: System Description

    Manual System description Device 1 Probe head 2 Probe connections 3 Display 4 Keypad 5 Calibration block Keys switch on device OFF: switch off device Arrow keys up / down / right: select decimal place and set sound velocity Shift key: switch between normal measurement mode, calibration mode and sound...
  • Page 6: Instructions

    Manual Instructions Calibration Press the shift key several times until CAL 0.0 is indicated in the LCD. Apply some coupling gel to the round steel block and press the test head firmly against the steel block (3 mm thick). The device is calibrated when 3.0 mm is displayed.
  • Page 7: Special Probes

    Manual Special probes Sensor / Measurement Surface Frequency Min. contact Shape material range temperature PCE-TG-ST 0.8 … 225 mm -10 … +50 °C 5 MHz 10 mm straight Standard test head for PCE- TG 100, for measurements of steel, non- ferrous materials, aluminium...
  • Page 8: Sound Velocities For Different Materials

    Manual Sound velocities for different materials The following chart lists the sound velocities of some materials. They are to be seen as a reference. The actual sound velocities of these materials can deviate due to material composition, porosity and temperature. Therefore, it is necessary to determine the exact sound velocity by testing a piece of the material in question by means of the meter.
  • Page 9: Surface Accuracy

    Manual Surface accuracy The highest accuracy is achieved when the surface to be tested as well as the counterface (back wall) are even. When the surface to be tested is coarse, the lowest thickness that can be measured increases because the sound running time rises with the increasing thickness of the coupling layer. On the other hand, the roughness of the counterface causes strong dispersions of the reflected echo und thus an inaccurate indication of the thickness measurement.
  • Page 10: Maintenance And Cleaning

    Manual Maintenance and cleaning Maintenance Warning: To prevent measuring errors and resulting injuries, please replace the batteries as soon as the battery symbol appears. If the battery voltage is insufficient, a battery symbol is indicated in the display. In this case, replace the two AA batteries immediately to avoid measuring errors and resulting hazards.
  • Page 11: Contact

    Manual Contact If you have any questions about our range of products or measuring instruments please contact PCE Instruments. PCE Instruments UK By post: PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF By phone: 02380 987 035 PCE Americas...