Maintenance - WAGNER FLEXIO 5000 Owner's Manual

Hide thumbs Also See for FLEXIO 5000:
Table of Contents

Advertisement

MAINTENANCE

REPLACING THE FILTER
Before every use, you should inspect the air filter
in the turbine to see if it is excessively dirty. If it is
dirty, follow these steps to replace it.
Attention
Never operate your unit without the air filter. Dirt
could be sucked in and interfere with the function
of the unit.
1.
Open up the Power Box cover. Press the tab and remove the
filter cover.
Remove the dirty filter from the turbine and replace. The smooth
side of the air filter must be placed toward the turbine.
Secure the cover back onto the turbine.
CLEANING THE AIR VALVE TUBE
If spray material ever enters the air valve tube,
i
follow the steps below.
1.
Pull the air tube (a) at the top from the nozzle. Screw off the
valve cover (b).
Remove the valve seal (c). Clean all the parts carefully. Make sure
to remove any material from valve seal housing area (d). Make
sure the holes underneath the housing are clear.
The air tube and valve seal (c) are only solvent-
resistant to a limited extent. Do not immerse in
solvent, only wipe.
Attention
2.
Place the valve seal (c) in the valve cover (b) with the pin facing
into the tube. Installing the valve seal into the valve cover will
be much easier if the valve cover is inverted.
3.
Turn the nozzle upside down and screw on the valve cover (with
valve seal inside) from underneath. Turning the nozzle upside
down will prevent the valve seal from falling out of the valve
cover during reinstallation.
4.
Place the air tube on the valve cover and on the nipple at the
nozzle.
14
1
1
(a)
(b)
(c)
2
3
4
EN
(d)
(c)
(b)

Advertisement

Table of Contents
loading

Table of Contents