Troubleshooting - WAGNER FLEXIO 5000 Owner's Manual

Hide thumbs Also See for FLEXIO 5000:
Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
Problem A: Little or no material flow
Problem B: Material leaking
Problem C: Spray pattern too thick,
runs and sags
Problem D: Spray jet pulsates
Problem E: Too much overspray
Problem F: Pattern is very light and
splotchy
*Thinning the material may be necessary but only after attempting
i
to achieve optimal spray performance by adjusting the various
controls.
This unit contains no servicable electrical parts. Do not attempt
to service yourself. Store indoors with the cord stored inside the
Power Box.
Have you tried the recommendations above and are still having
problems? In the United States, to speak to a customer service
representative, call our Technical Service at 1-800-328-8251.
See www.wagnerspraytech.com in the "Contact Us" section for
Technical Service hours.
CAUSE
1. Nozzle clogged.
2. Suction tube clogged.
3. Air vent on suction tube blocked.
4. Material flow setting too low.
5. Suction tube loose.
6. No pressure build up in container.
7. Air valve tube not functioning.
8. Nozzle seal missing.
9. Air filter clogged.
10. Spray material too thick.
1. Nozzle loose.
2. Nozzle worn.
3. Nozzle seal missing or worn.
4. Material build-up on air cap and nozzle
1. Material flow setting too high.
2. Air power setting too low.
3. Applying too much material.
4. Nozzle clogged.
5. Air filter clogged.
6. Too little pressure build-up in container.
7. Spray material too thick.
1. Material in container running out.
2. Air filter clogged.
3. Air valve tube disconnected.
4. Suction tube clogged.
5. Air vent on suction tube blocked.
1. Gun too far from spray object.
2. Air power setting too high.
1. Moving the spray gun too fast.
2. Material flow setting too low.
3. Air power setting too high.
EN
SOLUTION
1. Clean.
2. Clean.
3. Clean (see page 13)
4. Increase material flow setting.
5. Remove and replace as tightly as possible.
6. Tighten container.
7. Make sure both ends of the tube are
connected and the valve seal is in place.
8. Replace nozzle (iSpray) or nozzle seal
(Detail Finish).
9. Change
10. Thin*.
1. Tighten the retaining ring.
2. Replace.
3. Replace nozzle (iSpray) or nozzle seal
(Detail Finish).
4. Clean.
1. Decrease material flow setting.
2. Increase air power setting.
3. Adjust material flow or increase
movement of spray gun.
4. Clean.
5. Change.
6. Tighten container.
7. Thin*.
1. Refill.
2. Change.
3. Reconnect both ends of the air tube.
4. Clean.
5. Clean (see page 13)
1. Reduce distance (6"-8" is ideal).
2. Decrease air power setting.
1. Adjust material flow or decrease
movement of spray gun.
2. Increase material flow setting.
3. Decrease air power setting.
15

Advertisement

Table of Contents
loading

Table of Contents