Arming Errors And Exit Faults; Arming Errors; Audible Exit Faults; Disarming The System - DSC neo HS2128 E User Manual

Alarm panel
Hide thumbs Also See for neo HS2128 E:
Table of Contents

Advertisement

Chapter
4
3.
Press or [9][9][1]. If required enter your [access code].
OR
Scroll to Bypass Options using the [<][>] keys and press [*]. Scroll to
Bypass Group and press [*].
4.
The group of zones are now bypassed. The following message
briefly displays.
5.
To exit bypassing mode and return to the Ready state, press [*].
6.
If using an LED or ICN series keypad, the will light and the
bypassed zones #s will be shown. If the system is ready to arm the
Ready indicator will be lit. When arming the system the following
message briefly displays.

4.10 Arming Errors and Exit Faults

The PowerSeries Neo audibly notifies you of any errors when you are attempting to arm the system or
exit the premises.
Arming
4.10.1
Errors
An error tone (long beep) sounds if the system is unable to arm. Arming errors occur if:
The system is not ready to arm (i.e., sensors are open).
l
An incorrect user code is entered.
l
A trouble is present and has not been viewed by the user. This operation must be enabled by the
l
installer.
To Correct an Arming Error
1.
Ensure all sensors are secure. Your keypad will identify all open zones.
2.
If the trouble light is on, enter [*][2] and enter [99] or scroll to the Acknowledge All Troubles prompt
and press [*], if your installer has configured your system to impede armingwhen a trouble is present.
3.
Try arming the system again. For details on arming the system, see one of the previous arming pro-
cedures.
4.
If errors persist contact your installer.

4.10.2 Audible Exit Faults

NOTE: Must be enabled by installer.
In an attempt to reduce false alarms, the Audible Exit Fault notifies you of an improper exit when arming
the system. Improper exits are caused by failing to securely close the Exit/Entry door.
Improper exits cause the following system notifications:
The keypad emits one continuous beep.
l
The bell or siren sounds for the duration of the entry delay until a valid user code is entered or
l
until the programmed Bell time out expires.
To correct an exit fault:
1.
Re-enter the premises.
2.
Disarm the system before the entry delay timer expires by entering your [access code].
3.
Follow the Away arming procedure again, making sure to close the entry/exit door properly. For
more details see: "Away Arming the System with the Keypad".

4.11 Disarming the System

Depending on your system configuration, there are multiple methods you can use to disarm/unset your
system. You can disarm the system using a 2-way wireless key or a proximity tag:
To disarm the system with a keypad:
1.
Enter your [access code] or present your proximity tag anytime the system is armed. (Armed
indicator is on).
2.
If you walk through the entry door, the keypad will beep. Disarm within _____ seconds to avoid an
alarm condition.
To disarm the system with a 2-way wireless key:
1.
Press the disarm button anytime the system is armed. (Armed
indicator is on).
-
-
16
Press (*) for <>
Bypass Group
Bypass Group
Zones Bypassed
* Warning *
Bypass Active

Advertisement

Table of Contents
loading

Table of Contents