Figure 8. Installing a 2.5" drive
The activity light flashes to indicate that the spin-up sequence has begun.

Verify the operation of an added drive

Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you added the drive.
3. On the Components card, under Drives, expand BaseEnclosure and select the drive.
The status of the drive should read Healthy. If the status is still Faulted, wait a few minutes and refresh PowerStore
Manager. If the status does not change, ensure that the drive is correctly seated, or contact your service provider.

Replace a power supply

Take the following actions to remove the faulted power supply and install the replacement power supply into the system.

Identify a faulted power supply from PowerStore Manager

Before you replace a power supply, ensure that you have identified its location within the system. Using PowerStore Manager,
you can identify and locate a faulted power supply.
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance that includes the power supply that you need to replace.
3. On the Components card, under Rear View, expand BaseEnclosure.
4. Expand the node that includes the power supply, and then select PSU0.
Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.
Base enclosure service procedures
15