App 11-13 - Danfoss APP 13 Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Operating guide
Data sheet
22 | 180R9264 | AQ115586503043en-000903
Installation, Operation and Maintenance APP 11-13

4.4 APP 11-13

Pump size
Code number APP
Code number APP ATEX
3)
cm³/rev.
Geometric
displacement
in³/rev.
Pressure
Max. outlet
barg
1)
pressure
psig
continuous
barg
Min. outlet
1)
pressure
psig
barg
Inlet pressure
continuous
psig
barg
Max. inlet
pressure. peak
psig
Speed
Min. speed
rpm
continuous
Max. speed
rpm
continuous
Typical flow - Flow curves available in item 5
1000 rpm at
m³/h
max. pressure
1500 rpm at
m³/h
max. pressure
1200 rpm at
gpm
max. pressure
Technical specifications
°C
Media
2)
temperature
°F
°C
Ambient
temperature
°F
kg
Weight (dry)
lb
Sound pressure
dB(A)
level
4)
Footprint with
IEC motor
5)
foot²
Typical motor size
Max. speed at
kW
max. pressure
1200 rpm at
HP
max. pressure
Nm
Torque at max.
outlet pressure
lbf-ft
1)
For lower and higher pressure, please contact Danfoss.
Dependent on the NaCI concentration - see chapter 8.
2)
4)
Category 2, Zone 1 or Category 3, Zone 2.
APP 11/1200
APP 11/1500
180B3212
180B3211
180B3222
180B3221
166.4
137.4
10.15
8.38
83
70
1200
1015
10
10
145
145
2 - 5
2 - 5
29 - 72.5
29 - 72.5
10
10
145
145
700
700
1200
1500
9.22
7.50
11.25
48.71
39.61
2 - 50
2 - 50
35.6 - 122
35.6 - 122
0 - 50
0 - 50
32 - 122
32 - 122
78
78
172
172
85
85
0.48
0.48
5.17
5.17
30.0
40.0
229
166
169
123
A-weighted sound pressure level at 1 m from the pump unit
4)
surfaces (reference box) acc. to EN ISO 20361 section 6.2.
The noise measurements are performed acc. to EN ISO 3744:2010
on a motor-pump unit at max. pressure and speed.
5)
Max. area covered with recommended motor configuration
(excl. of space to service pump)
APP 13/1200
APP 13/1500
180B3214
180B3213
180B3224
180B3223
197.5
166.4
12.05
10.15
83
70
1200
1015
10
10
145
145
2 - 5
2 - 5
29 - 72.5
29 - 72.5
10
10
145
145
700
700
1200
1500
11.07
9.23
13.84
58.51
48.75
2 - 50
2 - 50
35.6 - 122
35.6 - 122
0 - 50
0 - 50
32 - 122
32 - 122
78
78
172
172
85
85
0.54
0.54
5.81
5.81
37.0
50.0
274
204
202
150