Danfoss APP Series Instruction
Hide thumbs Also See for APP Series:

Advertisement

MAKING MODERN LIVING POSSIBLE
Instruction
APP pump instruction
APP (W) 5.1-10.2
ro-solutions.com

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss APP Series

  • Page 1 MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP (W) 5.1-10.2 ro-solutions.com...
  • Page 2: Table Of Contents

    INSTRUCTIONS Instruction APP pump instruction APP (W) 5.1-10.2 Water Pump Table of Contents Identification ................2 type APP 5.1/5.6/7.2/8.2/10.2 System design .
  • Page 3: Open-Ended Systems With Water Supply From Tank

    fl ow area, minimum pipe length, minimum number of bends/ perte de charge minimale (grand diamètre, conduite courte, un hose. connections, fi ttings with small pressure losses). minimum de courbes, raccords avec faibles pertes de charge). Re 2.1. Sistema abierto a presión atmosférica 4) If noise has to be considered, the inlet line must be a fl...
  • Page 4: General Guidelines For Calculation Of Pressure Losses

    Wenn Umkehrpumpen hohem Druck in der Auslassleitung ausgesetzt werden – während der Elektromotor nicht eingeschaltet ist – werden die Pumpen rückwärts larufen. Re 2.3. Bomba reversible Solange der Einlassdruck den max. Druck von 5 bar nicht übersteigt, Si se expone la salida de la bomba a alta presión mientras qu werden die Pumpen vom Rückwärtslauf nicht beschädigt.
  • Page 5: Building Up The Pump Unit

    1. Identifi cation 1. Bezeichnung 1. Identifi cación Elastic coupling Bell housinge If alternative mounting is desired, please contact the Danfoss Sales Si vous désirez un autre type de montage, contactez l’organisation Motor shaft Organization. commerciale de Danfoss. Choose proper tolerances to ensure an easy mounting of the elastic Choisissez des tolérances correctes pour faciliter le montage sans outils...
  • Page 6: Protection From Too High Pressures

    The valve should be placed as close to the pump as possible. La vanne sera placée aussi près que possible de la pompe. 3.4 Überdruckabsicherung 3.4 Protección contra las altas presiones The opening characteristics of the valve must not result in peak Les caractéristiques d’ouverture de la vanne doivent permettre d’éviter Die Pumpe sollte mit einem Überdruckventil oder einem Druckent- La bomba se debe proteger de las altas presiones por m...
  • Page 7: Initial Start-Up

    For further information on anti-freeze media, please contact the Danfoss High Pressure Pumps. Max. pressure on the pump’s outlet line should be limited at 80 barg (1160 psig) continuously.
  • Page 8: Open-Ended Systems With Direct Water Supply

    The APP (W) pump is designed so that lubrica- In case of irregular function in the pump, please tion follows from the water itself and there is contact the Danfoss High Pressure Pumps. thus no oil in the pump. The pump requires no periodic replacements of seals and valve parts.
  • Page 9: Ec Declaration Of Conformity

    EC Declaration of Conformity 180R9072 / 521B0747 / DKCFN.PI.010.D5.02 / 11.2014...
  • Page 10 Denmark Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

This manual is also suitable for:

App 5.1App 10.2

Table of Contents