Operating guide
Data sheet
7.
Motor requirements
© Danfoss | 2023.03
Installation, Operation and Maintenance APP 11-13
The power requirements can be determined using one of the following guiding equations:
l/min x barg
Required power =
Calc. factor
1 hp
=
0.75 kW
1 gpm
=
3.79 l/min
1 m
/h
=
4.40 gpm
3
1 kW
=
1.34 hp
1 l/min
=
0.26 gpm
1 gpm
=
0.23 m
/h
3
7.4
Calculation factor for APP 11-13
Name
rpm
APP 11
1200
APP 11
1500
APP 13
1200
APP 13
1500
16.7 x m
/h x barg
3
[kW] or
Calc. factor
Calculation
factor
513
502
516
505
180R9264 | AQ115586503043en-000903 | 25
0.´35 x gpm x psig
[kW] or
[hp]
Calc. factor
Need help?
Do you have a question about the APP 13 and is the answer not in the manual?
Questions and answers