Replacing The Battery - IBM eserver xSeries 450 Option Installation Manual

Hide thumbs Also See for eserver xSeries 450:
Table of Contents

Advertisement

Replacing the battery

When replacing the battery you must replace it with a lithium battery of the same
type, from the same manufacturer. To avoid possible danger, read and follow the
safety statement below.
To order replacement batteries, call 1-800-772-2227 within the United States, and
1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada,
call your IBM reseller or IBM marketing representative.
Note: After you replace the battery, you must reconfigure your server and reset the
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
Complete the following steps to replace the battery:
1. Read the safety information beginning on page v and "Installation guidelines" on
2. Turn off the server and peripheral devices, and disconnect the power cords and
3. Remove fans 3 and 4 from the server (see "Replacing fan 3 or 4" on page 33
system date and time.
page 11. Follow any special handling and installation instructions supplied with
the replacement battery.
all external cables from the server; then, open the cover (see "Opening the
cover" on page 14 for details).
for details).
Chapter 2. Installing options
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sc88-p919-40

Table of Contents