Laversab 6300-M4 User Manual page 48

Table of Contents

Advertisement

2.
Press GO to execute the flashing profile point. Once the 6300-M4 achieves the state it
has been commanded to go to, it will stay there until the next profile point is invoked (using
ENTER) and executed (using GO).
3.
Press ENTER to invoke the next profile point. All parameters of the point will be
shown on the screen and the point number will flash on line 4. ENTER allows the user to
view an entire profile without executing any point. It also allows the user to skip certain
points if so desired.
4.
Only the ARROW keys are effective during profile execution to allow the user to jog
the profile's target values. A new target value cannot be entered while a profile is executing.
The existing target value may be jogged up or down in fixed increments as described in
section 3.2.2.
5.
No other keys are effective. Changing units or modes or target values will require
aborting the profile.
6.
When a profile goes into leak mode, the Leak Screen will be displayed. The profile will
stay in this screen until the user enters CANCEL to exit the leak screen. The 6300-M4 returns
to the main screen where the user must press ENTER to invoke the next profile point.
7.
When the last point in the profile is executed, pressing ENTER will cause line 4 of the
display to be cleared. This will be the only indication that the profile has been completed.
8.
Each profile can have up to 50 points. There can be 20 profiles resident in the 6300-M4
at any one time.
9.
New profiles can be loaded any number of times. They have to be numbered 1 to 20
and will overwrite existing resident profiles with the same profile number.
10.
Errors during profile execution will cause the profile to abort. It can be restarted by the
user at the point where the error occurred, after the error is rectified.
11.
If a particular test procedure requires more than 50 points, then these points can be
split between 2 or more profiles. For instance, if a transponder test requires 80 points, then
the first 50 points can be loaded as profile 1 and the remaining 30 points can be loaded as
profile 2. When profile 1 has been completed at point 1.50, the 6300-M4 will stay at that point
until the next command. The user can start profile 2.1 and execute the 51st point and continue
through the remaining 30 points using profile 2.