Mira Mode 1.1980.001 Installation And User Manual page 59

Digital shower / bathfiller
Table of Contents

Advertisement

Symptoms
Interface On / Off
Button Flashing
(2 times a second)
Temperature
Indicator Ring and
Interface On / Off
Button flashing
(2 times a second)
Error
Code
4
Outlet thermistor not detected - Contact Mira customer services team.
User Interface stuck button detected. Check user interface button
operation then power off the product for 30 seconds or reset the
N/A
product in the Mira Showers app. If the error re-appears, please
contact Mira customer services team.
37 or
A software error has been detected. Try powering off the product for
40
30 seconds or resetting in the Mira Showers app.
DO NOT ATTEMPT TO OPERATE YOUR PRODUCT. A temperature
of less than 0°C has been detected in your product which could have
caused internal damage leading to potential leaks.
It is essential that your product is protected from freezing conditions
otherwise serious damage can occur.
Warning! If the valve module has been subjected to freezing conditions
it may require inspection to ensure internal damage has not occurred,
(contact your installer). If no sign of leaks, reset the product by powering
off for 30 seconds or re-setting in the Mira Showers app. Ensure there
are no leaks when the shower is first used.
11 or
111
DO NOT ATTEMPT TO OPERATE YOUR PRODUCT. A temperature
of less than 0°C has been detected in your product which could have
caused internal damage leading to potential leaks.
It is essential that your product is protected from freezing conditions
otherwise serious damage can occur.
Warning! If the valve module has been subjected to freezing conditions
it may require inspection to ensure internal damage has not occurred,
(contact your installer). If no sign of leaks, reset the product by powering
off for 30 seconds or re-setting in the Mira Showers app. Ensure there
are no leaks when the shower is first used.
An outlet solenoid error has been detected. Try powering off the product
45
for 30 seconds or resetting in the Mira Showers app.
No (or very low) flow has been detected by the product. This may
50
be indicated by a low or no flow from the product. Refer to diagnosis
section 4b.
Unusually high flow has been detected. Try powering off the product
54
for 30 seconds or resetting in the Mira Showers app.
Hot inlet temperature is above 85°C. Reduce temperature of combi
112
boiler or tank thermostat.
Outlet, temperature too hot. Try powering off the product for 30
3 or 7
seconds or resetting in the Mira Showers app. Refer to diagnosis
section 4d.
Description and Remedial Action
59

Advertisement

Table of Contents
loading