Mira Mode 1.1980.001 Installation And User Manual page 24

Digital shower / bathfiller
Table of Contents

Advertisement

4
Connect the hot and cold inlet supply pipework to the digital mixing valve.
Note: DO NOT use any type of jointing paste or compound on any pipework
or fittings supplying the digital shower valve. These can build up within the
product and reduce the performance or cause early failure.
Note: Only use suitable 15mm pipework when connecting to the push-fit
connectors.
Note: The inlet pipework must be flexible enough to allow 25 mm movement to
enable filters to be removed for cleaning and for maintenance of the internal
components. Failure to achieve this may result in service and repair not being
able to be carried out.
Note: Flush pipework before connecting inlet pipes to digital mixing valve.
Failure to flush pipework may cause debris to block filters an impair product
performance.
Isolating valves must be installed to both inlets (supplied) and it is recommended to
fit isolators on the outlet, close to the digital mixing valve for ease of maintenance.
Note: The direction of the arrow on the isolation valve indicates direction of flow.
Run the pipes from the mixed water outlets on the digital mixing valve to the proposed
siting for the shower hose outlet, and overhead fixed arm, depending on the system
chosen.
Hot Inlet
Push-fit Isolators
fitted to both Inlets
24
Cold Inlet
Outlet 1 - Handset
Outlet 2 - Overhead / Bathfiller
Push-fit connector to the shower outlets

Advertisement

Table of Contents
loading

Table of Contents