The letter X in the certificate number
indicates that the equipment is subject to
special conditions for safe use. The
conditions are mentioned in the certificate
and in these installation and operating
instructions.
Special conditions for safe use of
explosion-proof pumps:
1. Bolts used for replacement must be
class A2-70 or better according to
EN/ISO 3506-1.
2. The pump must not run dry. The level
of pumped liquid must be controlled by
two stop level switches connected to
the motor control circuit. The minimum
level depends on the installation type
and is specified in these installation
and operating instructions. The pumps
can be used in duty cycles S3, halfway
submerged, or S1, fully submerged.
3. Make sure the permanently attached
cable is suitably mechanically
protected and terminated in a suitable
terminal board placed outside the
potentially explosive area. The power
cable plug may only be disconnected
by the manufacturer or his
representative.
4. The thermal protector in the stator
windings has a rated cut-out
temperature of 150 °C guaranteeing
the disconnection of the power supply.
The power supply must be reset
manually.
5. The IP68 rating is limited to maximum
10 m submersion depth.
6. The temperature range is limited to -20
to +40 °C for ambient temperature and
0-40 °C for liquids.
7. Contact the manufacturer regarding the
"d" protection type for pumps and for
information on the dimensions of the
flameproof joints.
8. The lock nut of the cable connector
must only be replaced with an identical
one.
Approvals
The standard version of SEG pumps has been tested
by VDE. The explosion-proof version of SEG has
been approved by DEKRA according to the ATEX
directive.

Approval standards

The standard version of SEG pumps has been
approved by Tüv Rheinland LGA according to EN
12050-1.
The explosion protection classification of the pumps
is Europe CE 0344
II 2 G Ex db llB T4 Gb.
Australia
For IEC countries, such as Australia and others, the
explosion-proof versions have been approved by
DEKRA, certificate no IECEx DEK 18.0038X, as Ex
db IIB T4 Gb according to IEC 60079-0:2017 and
IEC 60079-1:2014 or certificate no IECEx KEM
06.0028X, as Ex nC II T3 according to IEC
60079-15:1987 (corresponding to AS 2380.9).
Nameplate
1
Type:
2
Model:
3
4
5
6
7
P.c
8
IP68
9
Hmax:
m
10
P1:
kW
11
n:
min
-1
12
Weight:
kg
13
opr.:
14
Made in Tatabánya, Hungary
15
DK-8850 Bjeringbro,Denmark
Fig. 1
Nameplate
Pos.
Description
1
Type designation
2
Product number
3
Approval
4
ATEX certificate number
5
IEC Ex description
6
IEC Ex certificate number
7
Production code, year and week
8
Enclosure class according to IEC 60529
9
Maximum head [m]
10
Rated input power [kW]
11
Rated voltage
12
Speed [rpm]
13
Net weight [kg]
14
Run capacitor [μF]
15
CE mark
16
Safety instructions, publication number
17
Ex description
28
Maximum installation depth [m]
29
Maximum flow rate [l/s]
20
Rated power output [kW]
21
Maximum current [A]
16
17
18
19
Qmax:
I/s
kW
P2:
20
21
22
Tmax:
°C
23
Hz
Insul.class:
24
25
26
11