Approvals; Approval Standards; Explanation To The Ex Approval; Iec Countries (Australia And Other Countries) - Grundfos SEG AUTOAdapt Service Instructions Manual

Hide thumbs Also See for SEG AUTOAdapt:
Table of Contents

Advertisement

5. Approvals

5.1 Approval standards

All versions have been approved by LGA (Notified body under the
Construction Products Directive) according to EN 12050-1.

5.2 Explanation to the Ex approval

The explosion-proof version has been approved by DEKRA
according to the ATEX directive. The explosion protection
classification of the SEG AUTO
II 2 G Ex b c d ib IIB T4 Gb.
Directive/
Code
standard
CE 0344
ATEX
II
2
G
Ex
b
c
d
Harmonised
European
ib
standard
IIB
T4
Gb

5.3 IEC countries (Australia and other countries)

For IEC countries, such as Australia and others, the explosion-
proof versions of SEG AUTO
ADAPT
by DEKRA, certificate no IECEx DEK 11.0026X, according to IEC
60079-0:2007, IEC 60079-1:2007 and IEC 60079-11:2006.
The explosion-protection classification of the pumps is Ex d ib IIB
T4 Gb.
Directive/
Code
standard
Ex
d
ib
IEC 60079-0,
IEC 60079-1 and
IIB
IEC 60079-11
T4
Gb
pump is Europe CE 0344
ADAPT
Description
CE mark of conformity according to the ATEX directive 2014/34/EU.
=
0344 is the number of the notified body which has certified the quality system for ATEX.
= Explosion protection mark.
Equipment group according to the ATEX directive, defining the requirements applicable to the
=
equipment in this group.
Equipment category according to the ATEX directive, defining the requirements applicable to the
=
equipment in this category.
= Explosive atmospheres caused by gases, vapours or mists.
= The equipment conforms to the harmonised European standard.
= Control of ignition sources according to EN 13463-6.
= Constructional safety according to EN 13463-5 and EN 13463-1.
= Flame-proof enclosure according to EN 60079-1:2007.
= Intrinsic safety enclosure according to EN 60079-11:2007.
Classification of gases according to EN 60079-0:2009.
=
Gas group B includes gas group A.
= Maximum surface temperature is 135 °C according to EN 60079-0.
= Equipment protection level (IEC).
pumps have been approved
Description
= The equipment conforms to the harmonised European standard.
= Flame-proof enclosure according to IEC 60079-1:2007.
= Intrinsic safety according to EN 60079-11:2007.
Classification of gases according to IEC 60079-0:2009.
=
Gas group B includes gas group A.
= Maximum surface temperature is 135 °C according to IEC 60079-0:2006.
= Equipment protection level.