Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
Connection example PNOZmulti Teaching in the actuator PSEN sl-0.5p 3.1 Installation Note regarding the free-moving actuator PSEN sl-0.5fm Installing on a swing gate Installing on a sliding gate Adjustment Operation Error display through flashing codes Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Page 4
Contents Dimensions in mm Technical Details Order No. 570570 Technical Details Order No. 570573 Supplementary data Radio approval Safety characteristic data Order reference Safety gate system Accessories EC declaration of conformity Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
PSEN sl-0.5p 3.1 Introduction Validity of documentation This documentation is valid for the product PSEN sl-0.5p 3.1. It is valid until new document- ation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
The following is deemed improper use in particular: Any component, technical or electrical modification to the product Use of the product outside the areas described in this manual Use of the product outside the technical details (see Technical details [ 26]). Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Have a good knowledge of the generic and specialist standards applicable to the spe- cific application. Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
1 signal output Magnetic guard locking for process protection Safety outputs switch independently of the status of the magnetic guard locking device 1 input to switch the locking magnet on/off LEDs for – Supply voltage/fault Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Inputs S11 and S21 are high. Safety outputs 12 and 22 are low if at least one of the following conditions are met: The actuator is outside the response range or Inputs S11 and S21 are low. Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Page 10
Error display [ 22]). Magnetic guard locking device and magnet monitoring The locking magnet is switched on if S31 (control command for magnetic guard locking) is high and the actuator is detected (safety gate closed). Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Max. lateral offset: 3 mm Wiring Please note: You must comply with the specifications stated in the technical details (see Technical details: System with normal actuator [ 26], System with free-moving actuator [ 29]). Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Cable type: LiYY 8x0.25 mm² (79 Ohm/km) from Pilz Max. load per safety output 100 mA 500 mA Cable length 65 m 28 m If cable lengths greater than those stated in the table are required, please contact Pilz. Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Pink 0 V UB Blue "Lock_Unlock" The wire colour also applies for the cable available from Pilz as an accessory. Connection to evaluation devices Make sure that the selected evaluation device has the following properties: 2-channel with feasibility monitoring OSSD signals are evaluated Operating Manual PSEN sl-0.5p 3.1...
Page 16
When several units are connected in series, the required current adds with the number of interconnected safety switches. The safety switch PSEN sl-0.5p 3.1 can be connected to Pilz evaluation devices, for ex- ample. Suitable Pilz evaluation devices are, for example:...
Input OSSD Input OSSD Signal input Lock/Unlock Teaching in the actuator PSEN sl-0.5p 3.1 Any corresponding Pilz actuator (see Technical details: System with normal actuator [ 26], System with free-moving actuator [ 29]) is detected as soon as it is brought into the response range.
Installation of the safety switch and actuator must be concealed. Alignment errors of the guard must not adversely affect the safety function of the guard. INFORMATION Mounting brackets are available as accessories [ 33]. Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
The actuators enable a warped gate to be closed. A gap may occur on the gate as a result. Make sure that the gap remains small enough to exclude the possibility of reaching into the danger zone. Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Align the safety switch and mounting bracket with the actuator and tighten the screws. Installing on a sliding gate Align the actuator mounting bracket flush with the sliding gate and tighten the screws. Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Page 21
(Important: do not tighten the screws) Fix safety switch upright with a screw (a), close gate. Align mounting brackets, press firmly together and tighten screw (b). Remove the safety switch and tighten screw (c). Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
"Input" LED lights up yellow: the signal switches from high to low at one input, while a high signal remains on the other input (partial operation). Remedy: Open both channels of the input circuit. Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Once, for one second each Code for 1st digit 4 times, for one second each Code for 2nd digit Once, for one second each Code for 3rd digit 3 times, short Code for error message repeated Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Page 24
Check cable length and too high (cable is shorten it, if necessary (see too long) max. cable length [ 12]) Other flashing codes signal an internal error. Remedy: Change device. Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Coding level in accordance with EN ISO 14119 Design in accordance with EN ISO 14119 Classification in accordance with EN 60947-5-3 PDDB Pilz coding type Coded Transponder Frequency band 122 kHz - 128 kHz Max. transmitter output 15 mW Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Page 27
Risk time in accordance with EN 60947-5-3 260 ms Supply interruption before de-energisation 15 ms ∞ Simultaneity, channel 1 and 2 max. Environmental data Temperature of metal surface at ambient temperat- ure: 25 °C 60 °C Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Page 28
Assured operating distance Sao 1 mm Typical operating distance So 2 mm Assured release distance Sar 15 mm 40 % Repetition accuracy switching distances Typ. Hysteresis 0,7 mm Min. distance between safety switches 30 mm Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
15 mW Electrical data Supply voltage 24 V Voltage Kind Voltage tolerance -15 %/+10 % Output of external power supply (DC) 4,8 W Max. inrush current at UB 0,6 A Max. switching frequency 1 Hz Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Page 30
25 °C 60 °C Ambient temperature EN 60068-2-14 In accordance with the standard Temperature range -25 - 55 °C Storage temperature EN 60068-2-1/-2 In accordance with the standard Temperature range -25 - 70 °C Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
Page 31
Typ. Hysteresis 0,7 mm Min. distance between safety switches 30 mm Sensor flush installation in accordance with EN 60947-5-2 Yes, follow installation guidelines Connection type M12, 8-pin male connector LiYY 8 x 0.25 mm2 Cable Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Accessories Product type Features Order no. PSEN sl bracket swing door Mounting bracket for swing gates and folding gates 570 550 PSEN sl bracket sliding door Mounting bracket for sliding gates 570 551 Operating Manual PSEN sl-0.5p 3.1 1003388-EN-04...
European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PSEN sl-0.5p 3.1...
Need help?
Do you have a question about the PSEN sl-0.5p 3.1 and is the answer not in the manual?
Questions and answers