Resetting - Printronix P7000 Programmer's Reference Manual

Ansi programmer’s reference manual
Hide thumbs Also See for P7000:
Table of Contents

Advertisement

Chapter
2
Configuring The ANSI Emulation

Resetting

ASCII Code ESC c
Hex Code
Dec Code
Expression CHR$(27);"c";
Purpose
Discussion The following attributes, which are not part of the configuration,
40
1B 63
27 99
Resets the printer's configuration parameters. Depending on
which option was selected in the "Reset Cmd CFG Ld" menu,
the parameters are set to the factory default configuration,
power-up configuration, or the current configuration. If "Reset
Cmd CFG Ld" is disabled in the menu, the hardcoded
parameters shown in Table 7 are set.
are also reset:
Character rotation is reset to no rotation.
Character expansions are set to 1x1.
Subscript and superscript are turned off.
Underscoring is turned off.
Plot mode is terminated.
The horizontal and vertical tabulation tables are cleared.
The default EVFU table is loaded.
Bar code parameters are set to default values.
Graphic line density is set to 60 horizontal DPI x 72 vertical DPI.
The current line is set as the top-of-form (TOF) position.
Table 7. Hardcoded Reset Values
Parameter
Font style
Character size
Character pitch
Country selection
Line spacing
Partial Line up
Partial Line down
Bold print
Underline mode
Expanded mode
Proportional mode
Horizontal tab table
Left margin
Right margin
Page size
Top margin
Bottom margin
Forms position
Vertical tab table
Vertical format unit
Graphics density
VFU load in progress
Bar code mode
Dot graphics
Setting
Data processing
1 x vertical; 1 x horizontal
10 CPI
Latin 1 8859-1
6 LPI
Reset
Reset
Disabled
Disabled
Disabled
Reset
Empty
None - column 0
None - Maximum
7920 decipoints/ 66 lines/ 11 inches
None
None
Top-of-form = current position
Empty
Default
60 Horizontal DPI, 72 Vertical DPI
Exit (nothing saved)
Disabled
Disabled

Advertisement

Table of Contents
loading

Table of Contents