Flash Memory Message Guide - Printronix P7000 Programmer's Reference Manual

Ansi programmer’s reference manual
Hide thumbs Also See for P7000:
Table of Contents

Advertisement

Flash Memory Message Guide

Message
CLEARING PROGRAM
FROM FLASH
DIAGNOSTIC PASSED
ERROR: DC PROGRAM
NOT VALID
ERROR: DRAM AT
ADDRESS XXXXXXXX
ERROR: EC PROGRAM
NOT VALID
ERROR: EC STOPPED AT
STATE XXXX
ERROR: FLASH DID NOT
PROGRAM
ERROR: FLASH NOT
DETECTED
ERROR: NO DRAM
DETECTED
ERROR: NVRAM FAILURE
ERROR: PROGRAM NEEDS
MORE DRAM
Explanation
The program successfully
loaded into printer RAM and
the checksum matched. The
old program is now being
deleted from flash memory.
The printer passed its
memory and hardware
initialization tests.
Printer cannot find the data
controller program or the
validation checksum is
corrupt.
The printer found a defective
memory location.
Printer cannot find the engine
controller program or the
validation checksum is
corrupt.
Hardware fault in the engine
controller.
The printer could not find any
flash memory.
The printer could not find any
flash memory.
The printer could not find any
DRAM.
The non-volatile memory has
failed.
The printer requires more
DRAM memory in order to run
the downloaded program.
Flash Memory Message Guide
Required Action
None
None
1. Download the program
again.
2. If the message occurs
again, replace the flash
memory.
Replace the DRAM.
1. Download the program
again.
2. If the message occurs
again, replace the flash
memory.
Replace the CMX controller
board.
1. Download the program
again.
2. If the message occurs
again, replace the flash
memory.
Install flash memory before
attempting to download this
program.
Check DRAM on CMX. If
present, reseat DRAM. If
missing, install DRAM.
Replace the CMX controller
board. (Do NOT attempt to
replace NVRAM.)
Add DRAM or use a smaller
emulation program.
19