3.5.7 Mode

The Mode option sets the output to the desired mode.
Navigate: MENU > Dx_OUT > Mode
Remote Input: Available
Default: Wnd
mode
The following table describes the sensor modes.
Mode
Description
Alarm
Alarm Mode: The Discrete Output is Off while a target is detected by the sensor at any distance.
When a loss of signal occurs, the Discrete Output is On.
This mode has no associated thresholds.
Health
Health Mode: The Discrete Output is On while a target is detected by the sensor at any distance.
When a loss of signal occurs, the Discrete Output is Off.
This mode has no associated thresholds.
Switch Mode: The Discrete Output is On while a target is detected nearer than the switch point threshold.
SPt
When a target is detected farther than the switch point threshold or the signal is lost, the Discrete Output is Off.
Switch Mode: The Discrete Output is Off while a target is detected nearer than the switch point threshold.
SPt
When a target is detected farther than the switch point threshold or the signal is lost, the Discrete Output is On.
Window Mode: The Discrete Output is On while a target is detected between the SPt1 and SPt2 thresholds.
Wnd
(Default)
When a target is detected outside the SPt1 and SPt2 thresholds or the signal is lost, the Discrete Output is Off.
Window Mode: The Discrete Output is Off while a target is detected between the SPt1 and SPt2 thresholds.
Wnd
When a target is detected outside the SPt1 and SPt2 thresholds or the signal is lost, the Discrete Output is On.
Remote Input Instructions
1. Access the setup mode.
Action
Double-pulse the remote input.
2. View the current mode.
Action
Double-pulse the remote input.
3. Program the sensor.
L-GAGE
T
T
T
T
T
T
www.bannerengineering.com - Tel: 763.544.3164
®
LE250/550 Dual Discrete Laser Gauging Sensors
Result
"REMOTE SETUP" displays.
Result
The current mode displays.