SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
PRODUCT APPLICATION Construction • The water purifier is designed to mount horizontally. • The water purifier’s chamber is passivated and electropolished type 304 Stainless Steel. • EASY-OFF End Caps enable quick and easy lamp change, without disconnecting from the water supply or draining the purifier.
INSTALLATION Location 1. The water purifier is intended for indoor use only. The water purifier is designed to mount horizontally. The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier, should be between 35°F and 100°F.
Dimensional Data Figure 2 – MIN-6 and MIN-9 Dimensional Drawing Table 2 – MIN-6 and MIN-9 Dimensional Data Model Inlet/Outlet MIN- 6 14-3/4″ 22-17/32″ 5-3/4″ 4-1/4″ 22″ 5-7/16″ 3/4″ MNPT MIN-9 21-7/8″ 29-17/32″ 5-3/4″ 4-1/4″ 29″ 5-7/16″ 3/4″ MNPT All specifications, dimensional data, etc. are approximate and subject to change without notice.
Installation: MIN-6 and MIN-9 120v 50/60Hz using ballast no.10-0508B / 230v 50/60Hz using ballast no.10-0504B IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES. 1. Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there is any damage to the purifier, power cord or plug.
® products. For the other devices that may be required for your application, please contact your local water treatment dealer, plumber or plumbing supplier. If you have any questions, please contact Atlantic Ultraviolet Corporation ® by phone or email: (631) 273-0500 – Sales@AtlanticUV.com...
MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “Water Quality” in the “Product Application” section. Ordinary maintenance consists of; • Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service. •...
Lamp Installation or Replacement MIN-6 and MIN-9 120v 50/60Hz using ballast no.10-0508B / 230v 50/60Hz using ballast no.10-0504B Figure 4 – Lamp Replacement – Step 1 Disconnect Power to Water Purifier and Remove Ground Connector – – – Step 2 Remove End Cap Step 3 Remove Socket...
Replacement of Broken Quartz Sleeve IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES. Broken Quartz is SHARP. It is recommended that protective glasses and gloves are worn when handling.
TROUBLESHOOTING Always disconnect power to the water purifier before performing any service or maintenance. IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel. Table 3 – Troubleshooting Problem Possible Cause Corrective Action Verify that the purifier is connected to a live Purifier not operating No electrical power power source.
WARRANTY & PRODUCT REGISTRATION We warrant this product to the original owner to be free from defects in material and workmanship when installed in accordance with Atlantic Ultraviolet Corporation specifications for a period of time as follows: ®...