ULTRAVIOLET WATER PURIFIERS
Models S2400C, S5,000C–S25,000C
High Capacity Systems
Read and Follow All Safety Instructions. Save These Instructions.
Installation, Operation & Maintenance
Our S2400C water
Extensive Product Information Available at:
purifier, used to build
Ultraviolet.com
Model S5,000C and up,
is certified to NSF
/ANSI
®
BuyUltraviolet.com
Standard 61 & 372.
1
Document No. 98-1132F5 • January
2020
©2020
Atlantic Ultraviolet Corporation
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SANITRON S5000C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Atlantic Ultraviolet SANITRON S5000C

  • Page 1 Our S2400C water Extensive Product Information Available at: purifier, used to build Ultraviolet.com Model S5,000C and up, is certified to NSF /ANSI ® BuyUltraviolet.com Standard 61 & 372. Document No. 98-1132F5 • January 2020 • ©2020 Atlantic Ultraviolet Corporation ®...
  • Page 2: Table Of Contents

    Model S2400C line of water purifiers. Models S5,000C and S10,000C through S25,000C High-Capacity Systems utilize the Model S2400C single lamp water purifier in various configurations. Questions that are not specifically answered by these instructions should be directed to the Factory. Atlantic Ultraviolet ®...
  • Page 3: Safety Warnings

    SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this purifier. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
  • Page 4: Product Application

    PRODUCT APPLICATION onstruCtion • The water purifier is designed to mount horizontally. • The water purifier’s dual heads are removable and may be rotated independently. (See Figure 3 – Recommended Positions of Inlet/Outlet Fittings in the “Installation” section.) facilitates ease of installation, maintenance or the retrofitting of an existing system.
  • Page 5: Installation

    INSTALLATION oCation 1. The water purifier is intended for indoor use only. The water purifier is designed to mount horizontally. The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier, should be between 35°F and 100°F.
  • Page 6: I Nstallation

    nstallation IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES. Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there is any damage to the purifier, power cord or plug.
  • Page 7: R Ecommended O Ptions

    The water purifier must be connected to the cold water line only. Inlet water temperature should not exceed 100°F. Installation requires that a 5-micron sediment filter or finer be installed, in line, prior to the water purifier. The sediment filter will stop or trap large particulates from entering the water purifier.
  • Page 8: Maintenance

    Originally issued April, 1966. ® NOTE: The recommended options above are available from Atlantic Ultraviolet Corporation or a distributor of their products. For the other devices that may be required for your application, please contact your local water treatment dealer, plumber or plumbing supplier.
  • Page 9: D Isposal Of M Ercury A Dded L Amp

    isPosal of erCury dded amPs Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and recycling of lamps containing mercury, along with Federal and State requirements visit LampRecycle.org. For more information on STER-L-RAY ®...
  • Page 10: L Amp I Nstallation Or R Eplacement

    nstallation or ePlaCement Figure 5 – Lamp Replacement Step 2 – Remove End Cap Step 3 – Withdraw Lamp Steps 4 & 5 – Remove Sockets Step 6 – Remove Lamp IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
  • Page 11: Q Uartz S Leeve I Nstallation Or R Eplacement

    uartz leeve nstallation or ePlaCement Figure 6 – Quartz Sleeve Installation or Replacement Step 4 – Remove Gland Nuts Step 5 – Remove Washer & O-Ring Step 6 – Remove Quartz Sleeve IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
  • Page 12: R Eplacement Of B Roken Q Uartz S Leeve

    ePlaCement of roken uartz leeve Figure 7 – Quartz Sleeve IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES. Broken Quartz is SHARP. It is recommended that protective glasses and gloves are worn when handling. Disconnect power to water purifier.
  • Page 13: Ptional Guardian ™ U Ltraviolet M Onitor S

    ® ® 12. Re-install O-Rings, Teflon washers, and static gland nuts. Be sure O-Rings are placed on quartz sleeve before Teflon washer. Tighten static gland nuts firmly by hand only, DO NOT USE HAND TOOLS. Tightening with hand tools is likely to cause quartz sleeve to break.
  • Page 14: Troubleshooting

    TROUBLESHOOTING Always disconnect power to the water purifier before performing any service or maintenance. IMPORTANT: This purifier is to be serviced ONLY by qualified, and appropriately licensed, personnel. Table 2 – Troubleshooting Problem Possible Cause Corrective Action Verify that the purifier is connected to a live Purifier not operating No electrical power power source.
  • Page 15: Technical Specifications

    TECHNICAL SPECIFICATIONS Table 4 – Technical Specifications Model: S5,000C S10,000C S15,000C S20,000C S25,000C S2400C Flow Rate (GPM): Flow Rate (GPH): 2400 5000 10000 15000 20000 25000 Inlet\Outlet Size: 2”m NPT 2”m NPT 2”m NPT 2”m NPT 2”m NPT 2”m NPT Number of Lamps: Lamp Model No.: 05-1311-R...
  • Page 16: Replacement Parts

    REPLACEMENT PARTS SANITRON S2400C odel ® Figure 10 – Exploded View S2400C...
  • Page 17 Table 5 – Replacement Parts S2400C 120v/60Hz 220-240v/50Hz RoHS 220-240v Item No. Description Part Number Part Number Part Number EASY-OFF™ End Cap 25-0389A 25-0389A 25-0389A Rubber O-Ring, Static Gland 00-0085A 00-0085A 00-0085A Steadfast™ Lead Wire & Socket 05-2400A 05-2400A 05-2400A Promate™...
  • Page 18: High Capacity Systems

    SANITRON HIGH CAPACITY SYSTEMS ® imensional Figure 11 – S2400C& S5,000C Dimensional Data...
  • Page 19: D Imensional D Ata S10,000C, S15,000C, S20,000C & S25,000C

    imensional Figure 12 – S10,000C, S15,000C, S20,000C, S25,000C Dimensional Data...
  • Page 20: Declaration Of Conformity

    MAINTENANCE NOTES...
  • Page 21 MAINTENANCE NOTES...
  • Page 22 MAINTENANCE NOTES...
  • Page 23 MAINTENANCE NOTES...
  • Page 24: User Assistance

    WARRANTY & PRODUCT REGISTRATION We warrant this product to the original owner to be free from defects in material and workmanship when installed in accordance with Atlantic Ultraviolet Corporation ® specifications for a period of time as follows: UV Water Purifier Chambers –...

This manual is also suitable for:

Sanitron s2400cSanitron s25000c