Atlantic Ultraviolet MIGHTY PURE MP22A Owner's Manual

Atlantic Ultraviolet MIGHTY PURE MP22A Owner's Manual

Germicidal ultraviolet water purifiers
Hide thumbs Also See for MIGHTY PURE MP22A:

Advertisement

Models MP16A, MP22A, MP36C & MP49C
Installation,
Operation &
Maintenance
Read and Follow
All Safety Instructions.
Save these Instructions.
Manufacturers / Engineers / Sales / Service
Germicidal Ultraviolet – Equipment & Lamps
375 Marcus Boulevard, Hauppauge, NY 11788
(631) 273-0500 • Fax: (631) 273-0771
Email: Sales@AtlanticUV.com
Shop Products at
AtlanticUltraviolet.com
———————————————
Learn More at Ultraviolet.com
1
Document No. 98-1376F9 • July
2022
©2022
Atlantic Ultraviolet Corporation
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIGHTY PURE MP22A and is the answer not in the manual?

Questions and answers

Denny Barclay
May 25, 2025

I changed my quartz tube and bulb. When putting the tube through it got mud in it twice. I cleaned it out. But I wonder if they’re mud in the unit. I have a sediment filter before the unit. Would it hurt to take drain plug out and turn water on see if dirty or muddy water comes out in a bucket. I have mp-22.

Subscribe to Our Youtube Channel

Summary of Contents for Atlantic Ultraviolet MIGHTY PURE MP22A

  • Page 1 Germicidal Ultraviolet – Equipment & Lamps 375 Marcus Boulevard, Hauppauge, NY 11788 (631) 273-0500 • Fax: (631) 273-0771 Email: Sales@AtlanticUV.com Shop Products at AtlanticUltraviolet.com ——————————————— Learn More at Ultraviolet.com Document No. 98-1376F9 • July 2022 • ©2022 Atlantic Ultraviolet Corporation ®...
  • Page 2: Table Of Contents

    Follow all instructions on any labels or tags. Carefully inspect all packing materials before discarding to prevent the loss of accessories, mounting hardware, spare parts or instructions. The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation and are believed to be correct. However, no ®...
  • Page 3: Safety Warnings

    SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
  • Page 4: Product Application

    PRODUCT APPLICATION onstruCtion • The water purifier is designed to mount horizontally. • A drain port on the chamber aids in draining of the purifier. • The water purifier’s chamber and chamber head are passivated and electropolished type 316 Stainless Steel. •...
  • Page 5: Installation

    INSTALLATION oCation The water purifier is intended for indoor use only. The water purifier is designed to mount horizontally. The water purifier should be protected from the elements and from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier, should be between 35°F and 100°F. Electrical power supplied to the water purifier MUST match power requirements listed on the water purifier.
  • Page 6: Ecommended Nstallation

    eCommenDeD nstallation IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES. Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there is any damage to the purifier, power cord or plug.
  • Page 7: Nitial Nstallation Of Uartz Leeve Odel Mp49C

    For Models with lamps packed separately, install lamp following the steps in “Lamp Installation or Replacement” section. Lamp and quartz sleeve are easily damaged. Exercise care when handling. Plug water purifier into approved ground fault circuit interrupt (GFCI) receptacle. Confirm lamp operation indication at sight port.
  • Page 8 Figure 3 – Initial Installation of Quartz Sleeve...
  • Page 9: Ecommended Ptions

    ® products. For the other devices that may be required for your application, please contact your local water treatment dealer, plumber, or plumbing supplier. If you have any questions, please contact Atlantic Ultraviolet Corporation ® by phone or email: (631) 273-0500 – Sales@AtlanticUV.com...
  • Page 10: Maintenance

    MAINTENANCE The water purifier is designed to operate with a minimal amount of maintenance, providing the water quality does not exceed maximum concentration levels, see “Water Quality” in the “Product Application” section. Ordinary maintenance consists of: • Lamp replacement is recommended every 10,000 hours of operation, approximately 12 months of continuous service. •...
  • Page 11: Eplacement

    nstallation or ePlaCement Figure 4 – Lamp Replacement Step 2 – Remove End Cap Step 3 – Withdraw Lamp Step 4 & 5 – Remove Sockets Step 6 – Remove Lamp IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
  • Page 12: Or Eplacement

    uartz leeve nstallation leaning ePlaCement Figure 5 – Quartz Sleeve Installation, Cleaning, or Replacement Step 4 – Remove Gland Nuts Step 5 – Remove Washer & O-Ring Step 6 – Remove Quartz Sleeve IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
  • Page 13: Eplacement Of Roken Uartz Leeve

    ePlaCement of roken uartz leeve IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES. Broken Quartz is SHARP. It is recommended that protective glasses and gloves are worn when handling. Disconnect power to water purifier.
  • Page 14: Leaning Of Ptional Guardian

    leaning of Ptional uarDian ermiCiDal ltraviolet onitor ensor roBe Figure 6 – Ultraviolet Monitor and Sensor Probe Figure 7 – Sensor Probe If after cleaning the quartz sleeve, there is no significant improvement in the ultraviolet intensity, as shown on the intensity meter, it may be necessary to clean the Ultraviolet Monitor’s sensor probe.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Always disconnect power to the water purifier before performing any service or maintenance. IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel. Table 3 – Troubleshooting Problem Possible Cause Corrective Action Verify that the purifier is connected to a live power Purifier not operating No electrical power source.
  • Page 16: Technical Specifications

    TECHNICAL SPECIFICATIONS Table 4 – Technical Specifications Model: MP16A MP22A MP36C MP49C Flow Rate (GPM): Inlet\Outlet Size: 3/4″ MNPT 3/4″ MNPT 1″ MNPT 1-1/2″ MNPT Number of Lamps: Lamp Model No.: 05-1098-R 05-1097-R 05-1343-R 05-1334-R Length: 16-1/2″ 22-1/2″ 36-1/2″ 49-1/2″ Width: 4-5/16″...
  • Page 17: Optional Accessories

    OPTIONAL ACCESSORIES Table 5 – Optional Accessories Most optional accessories are Optional Accessories Available For: available for operation at 120v 60Hz GUARDIAN™ Germicidal Ultraviolet Monitor – Analog/Digital MP16A through MP49C or 220v 50Hz. Please specify. Consult GUARDIAN™ ASSIST Germicidal Ultraviolet Monitor Extension MP16A through MP49C Factory for 12v DC or other special input power requirements.
  • Page 18: Replacement Parts

    REPLACEMENT PARTS MIGHTY«PURE ® mP16a & mP22a oDels Figure 8 – Exploded View MP16A & MP22A...
  • Page 19 Table 6 – Replacement Parts MP16A & MP22A MP16A MP22A Item No. Description Quantity Part Number Quantity Part Number EASY-OFF™ End Cap 25-1499A1 25-1499A1 O-Ring, Static Gland 00-1108B 00-1108B Steadfast™ Lamp Spacer 25-0208A 25-0208A 05-2223A 05-2223A Steadfast™ Lead Wire & Socket 05-1098-R 05-1097-R ®...
  • Page 20: Mighty"Pure ® M Odels Mp36C & Mp49C

    MIGHTY«PURE ® mP36C & mP49C oDels Figure 9 – Exploded View MP36C &MP49C...
  • Page 21 Table 7 – Replacement Parts MP36C &MP49C MP36C MP49C Item No. Description Quantity Part Number Quantity Part Number EASY-OFF™ End Cap 25-1499A1 25-1499A1 O-Ring, Static Gland 00-1108B 00-1108B Steadfast™ Lamp Spacer 25-0208A 25-0209A 05-1218A2 05-1218A2 Steadfast™ Lead Wire & Socket 05-1343-R 05-1334-R ®...
  • Page 22: Maintenance Notes

    MAINTENANCE NOTES...
  • Page 23 MAINTENANCE NOTES...
  • Page 24: User Assistance

    WARRANTY & PRODUCT REGISTRATION We warrant this product to the original owner to be free from defects in material and workmanship when installed in accordance with Atlantic Ultraviolet Corporation specifications for a period of time as follows: ®...