7
If the transducer has been installed in a drop keel:
a
Verify that the cables can move freely during lowering and hoisting of the drop
keel.
b
Verify that there are no sharp edges or protruding elements that may cause damage
to the cables during lowering and hoisting.
c
Verify that the cables are not bent too tightly under during lowering and hoisting.
8
Use a high resolution digital camera, and take pictures of the installation.
The pictures must clearly show how the transducer and the transducer cables are
installed. Attach the pictures (files and/or prints) to the test report.
Related topics
Setting to work summary, page 206
Inspecting the MS70 installation, page 208

Verifying that all MS70 cables are properly connected

The MS70 relies on communication between each system unit, and between the MS70 and
external devices. It is very important that all cables are correctly installed, that the proper
cable types have been used, and that all cables are connected correctly.
Prerequisites
• The MS70 is installed as specified in the MS70 Installation manual.
• The MS70 has been set up with its hardware units connected as specified in the MS70
Installation manual.
• All system cables are installed.
• All cable connections are made.
• Correct operating power is available.
You need the following equipment:
• Cable tester
• Multimeter
Context
All cabling is described in the Cable layout and interconnections chapter. Refer to the cable
plan, the cable list and the basic cable requirements.