8.4

Higher hot water temperature

NOTE! Never connect the heat pump to provide a higher
temperature unless the heating or hot water systems require
it. Higher temperatures increase the load on the heat pump.
If necessary, the heat pump can be connected to produce hot-
ter water for the heating system and hot water system when it is
installed.
A
Figure 40: The pressure switches are installed on the compressor's
pressure pipe.
1. Move the grey cables, which are normally connected to pres-
sure switch A, to pressure switch B.
B
VMBME102