Piping Installation; Connection Diagram - Danfoss DHP-AL Installation And Service Instructions Manual

Table of Contents

Advertisement

5

Piping installation

NOTE! To prevent leaks ensure that there are no stresses in
the connecting pipes!
NOTE! It is important that the heating system is completely
bled after installation.
NOTE! Bleed valves must be installed where necessary.
5.1

Connection diagram

Pipe connections in image:
2
Water heater, return pipe
4
Heating system supply pipe
5
Heating system return pipe
8
Heating system, return pipe
9
Bleed valve, at stainless steel water heater
11 Tap hot water
12 Cold water
13 Water heater, supply pipe to TWS coil
6
4
5
10
7
1
Figure 20: General connection diagram.
12
Strainer
6
3
Figure 19: Principle solution for a pipe installation.
2
3
11
12
13
14
8
9
18
17
7
• Ensure that the piping installation follows the dimension and
connection diagrams in section "Heat pump information".
• Piping installation must be carried out in accordance with appli-
cable local rules and regulations. The hot water tank must be
equipped with an approved safety valve (supplied).
Safety valve (not included)
Mixer valve
Filler cock
5
4
Heat pump
2
1
Position Name
15
1
Heat pump
2
Supply pipe
16
3
Return pipe
4
Safety valve (not included)
5
Expansion tank (not included)
6
Strainer
7
Flexible hoses
8
Bleed valve
9
Mixer valve
10
Exchange valve
11
Safety valve (9 bar)
12
Vacuum valve
13
Non-return valve
14
Shut-off valve
15
Cold water
16
Hot water
17
Water heater
18
Bleed valve at stainless steel water heater
VMBME102
Safety valve 9 bar
14
10
13
11 12
9
Water heater
8
7
Bleed valve
Bleed valve at stainless
steel water heater

Advertisement