Ball Valve With Bernard Actuator - GEM B56 Operating Instructions Manual

Motorized compact flanged ball valve
Hide thumbs Also See for B56:
Table of Contents

Advertisement

6 Order data

6.3 Ball valve with Bernard actuator

The order data provide an overview of standard configurations.
Please check the availability before ordering. Other configurations available on request.
Products ordered with bold marked ordering options are so-called preferred series. Depending on the nominal size, these are
available more quickly.
Order codes
1 Type
Ball valve, metal, electrically operated, one-piece body,
compact flange,
low-maintenance spindle seal and blow-out proof shaft,
with anti-static unit
2 DN
DN 15
DN 20
DN 25
DN 32
DN 40
DN 50
DN 65
DN 80
DN 100
3 Body/ball configuration
2/2-way body
2/2-way body, V-ball 30°
(for Kv value see datasheet)
2/2-way body, V-ball 60°
(for Kv value see datasheet)
2/2-way body, V-ball 90°
(for Kv value see datasheet)
4 Connection type
Flange ANSI Class 125/150 RF
Flange EN 1092, PN 16/PN40, form B DN 15 to DN 80,
flange EN 1092, PN 16, form B DN 100 only
5 Ball valve material
1.4408 / CF8M (body, connection), 1.4401 / SS316
(ball, shaft)
6 Seal material
PTFE
7 Voltage/Frequency
230V 50Hz
24VDC 85-260VAC
8 Control module
ON/OFF actuator, 2 additional potential-free limit
switches,
additional potential-free torque switches, Class A
(EN15714-2)
ON/OFF actuator, 2 additional potential-free limit
switches,
Class A (EN15714-2)
GEMÜ B56
Code
8 Control module
B56
ON/OFF actuator, potentiometer output, Class A
(EN15714-2)
ON/OFF actuator, analogue position feedback, external
set value 0/4-20mA,
2 additional potential-free limit switches
Code
Control actuator, external set value 0/4-20 mA
15
ON/OFF actuator, on-site control, 2 additional potential-
20
free limit switches,
25
Basic (Logic ON/OFF), (S4 30% duty, 120 starts/hour,
actuator class A/B)
32
Position control, external set value 4-20mA, input and
40
output, on-site control,
50
2 additional potential-free limit switches,
65
Basic (Logic Positioner), (S4 50% duty, 360 starts/hour,
actuator class C)
80
100
9 Actuator version
Code
Actuator, motorized, operating time 13s, torque 15Nm,
BERNARD, type AQ
D
2 additional limit switches, heating,
U
manual override, aluminium housing, RAL5002, IP67
Actuator, motorized, operating time 15s, torque 30Nm,
Y
BERNARD, type AQ
2 additional limit switches, heating,
W
manual override, aluminium housing, RAL5002, IP67
Actuator, motorized, operating time 15s, torque 70Nm,
BERNARD, type AQ
Code
2 additional limit switches, heating,
39
manual override, aluminium housing, RAL5002, IP67
68
Actuator, motorized, operating time 30s, torque 150Nm,
BERNARD, type AQ
2 additional limit switches, heating,
Code
manual override, aluminium housing, RAL1014, IP68
37
Actuator, motorized, operating time 30s, torque 250Nm,
BERNARD, type AQ
2 additional limit switches, heating,
Code
manual override, aluminium housing, RAL1014, IP68
5
10 Type of design
Code
Standard
L2
Media wetted area cleaned to ensure suitability for paint
applications, parts sealed in plastic bag
Y5
Media wetted parts cleaned for high purity media and
Code
packed in plastic bag
AB
Valve free of oil and grease, media wetted area cleaned
and packed in PE bag
Thermal separation between actuator and
valve body via mounting kit
AE
Thermal separation between actuator and valve body
via mounting kit,
mounting kit and mounting parts made from stainless
steel
12 / 48
Code
AP
AT
E2
ALS
ELS
Code
BC1L
BC3L
BC7L
BC15
BC25
Code
0101
0104
0107
5222
5227
www.gemu-group.com

Advertisement

Table of Contents
loading

Table of Contents