Settings

■ Automatic settings and auto area learn

NOTE
Please check the dipswitch settings and detection area before executing.
• Dipswitch (→ see "Dipswitch settings")
• Detection area (→ see "Detection area adjustment")
Execute the following with the function switch on the OA-607 T front or with the setting app.
Auto configuration : E LITE PRO has an advance learning system that can recognize the following system configuration and status and set
the related parameters properly and automatically for easy and quick settings.
After parameter settings, it automatically starts auto area learn to setup the area for each OA-607 T sensor heads to
complete auto configuration.
▪ Test input (Enable/Disable)
▪ Test input polarity (High/Low)
▪ Stall output (N.O./N.C.)
▪ Sensor side (Approach/Swing side)
▪ Hinge side (Right Hand/Left hand)
Auto area learn : OA-607 T has a learning system that check the condition of floor surface for door opening angles.
WARNING
WARNING
The door opens and closes automatically, so move away from it after starting.
Conditions
Procedure
for
Operation
operation
Hold down the
During initial
Door fully
function switch
setup
closed
(more than 2 s)
When
adjusting
Briefly press the
the angle
None in
front function switch
or changing
particular
(more than 0.3 s, no
the settings
more than 2 s) once
after auto
configuration
*1: Twice or three times in accordance with the door controller signal input setting (combination of stall signal and test signal, etc.) during auto
configuration.
NOTE
B efore executing auto configuration, the connection between the door controller and the OC-907C T sensor controller must be complete.
Auto configuration must be started with the door fully closed. Otherwise, a setting error will be generated.
Function switch
Operation
Auto configuration start
Execute auto configuration
The door will open and close two or
three times automatically (*1).
Upon failure, after checking the
wiring, execute auto configuration
again.
If there is no problem with the wiring,
manual setting from a smart device is
also possible.
After installation is complete, leave
the power on for at least 30 min in
order to achieve stable operation
during use.
Start auto area learn only
Execute auto area learn only
Upon failure, before execution, check
that there are no obstacles to the
door and execute auto area learn
again.
As well, the power must not go off
immediately after auto area learn
completion (before auto-saving the
settings).
Check in advance that the door is fully closed.
Result
OA-607 T
operation indicator
Blinking fast in Orange (0.1 s intervals)
= Auto configuration start
Solid Green after normal completion
= Setup complete (stand-by)
Upon failure:
Blinking Orange (0.5 s intervals)
(= Setting error)
Blinking fast in Yellow (0.1 s intervals)
= Start auto area learn only
Solid Green after normal completion
= Setup complete (stand-by)
If the door is prevented from opening
by an obstacle or the power is cut just after
auto area learn is complete:
blinking alternately Yellow and Red
(0.1 s intervals)
= Incomplete