Walk Test; Inform Building Owner/Operator Of The Following Items; Troubleshooting - Optex ELITE PRO Instruction Manual

Hide thumbs Also See for ELITE PRO:
Table of Contents

Advertisement

Walk test

1
The approach side sensor detects entrance into the area while the door is fully closed, fully open, or opening/closing and
checks that the door is open or will open again.
2
The swing side sensor detects entrance into the area while the door is fully closed or opening and checks that the door
stops or creeps.
Upon failure, confirm the following
• Detection area (→ see "Detection area adjustment")
• Door controller wiring (→ see "Wiring")
• Settings (dipswitches or smart device) (→ see "Settings")
• Background learning again (→ see "Automatic settings and auto area learn")

Inform building owner/operator of the following items

1
When turning the power ON, stay clear of detection area for a minimum of 10 s, and then conduct a walk test in detection
area to ensure proper operation.
2
Always keep the detection window clean. If dirty, wipe the detection window with a damp cloth (do not use any cleaner or
solvent).
3
Do not wash the sensor with water.
4
Do not disassemble, rebuild or repair the sensor yourself, otherwise electric shock may occur.
5
Contact your installer or the sales engineer if you want to change the settings.
6
Do not place an object that moves or emits light in the detection area. (ex. plant, illumination etc.)
7
Do not paint the detection window.

Troubleshooting

■ OA-607 T
■ OC-907C T
● Operation indicators in the event of trouble
Indicator
Symptom
diagram
Configuration
error
Orange
(System setting)
blinking
(0.5 s intervals)
Operation indicator
Operation indicator
Procedures
Possible cause
Before initial setup
Power ON
Changed sensor composition after auto
configuration
Start auto
Executed auto configuration except the
configuration
door fully close
Abnormal sensor position
After door fully
closed
Failure sensor position recognition
Possible countermeasure
Execute auto configuration
Execute auto configuration at fully close position
Verify proper install the sensor
Adjust door open/close speed or set by setting app