When installation of the system is already completed
15.3 Relocation
FXSN50~112A2VEB
CO₂ Conveni-Pack: indoor unit
4P602817-1 – 2020.02
c
Service cover with wiring diagram
2 Turn ON the power supply.
3 Start fan only operation (see the reference guide or the service manual of the
user interface).
4 Remove the water inlet cover (1 screw).
5 Gradually pour approximately 1 l of water through the water inlet, and check
for leaks.
e
a
Water inlet
b
Portable pump
c
Water inlet cover
d
Bucket (adding water through water inlet)
e
Drain outlet for maintenance
f
Refrigerant pipes
6 Turn OFF the power.
7 Disconnect the electrical wiring.
▪ Remove the service cover.
▪ Disconnect the power supply and user interface.
▪ Reattach the service cover.
1 Start cooling operation (see the reference guide or the service manual of the
user interface).
2 Gradually pour approximately 1 l of water through the water inlet, and check
for leaks (see
"When installation of the system is not yet
Contact your dealer for removing and reinstalling the total unit. Moving units
requires technical expertise.
f
a
c
d
b
15
Unit installation
|
4
completed" [
54]).
Installer and user reference guide
55