9 Relocation

WARNING
Stop operation and shut OFF the power if anything
unusual occurs (burning smells etc.).
Leaving the unit running under such circumstances may
cause breakage, electrical shock or fire. Contact your
dealer.
The system MUST be repaired by a qualified service person.
Malfunction
If a safety device such as a fuse, a
circuit breaker or a residual current
device frequently actuates or the ON/
OFF switch does NOT function properly.
If water leaks from the unit.
The operation switch does NOT function
properly.
If the user interface displays
If the system does NOT operate properly except for the above
mentioned cases and none of the above mentioned malfunctions is
evident, investigate the system in accordance with the following
procedures.

For the installer

11

About the box

11.1

Indoor unit

WARNING: MILDLY FLAMMABLE MATERIAL
The R32 refrigerant (if applicable) in this unit is mildly
flammable. Refer to the outdoor unit specifications for the
type of refrigerant to be used.
11.1.1
To remove the accessories from the
indoor unit
1 Remove the accessories from the side of the unit. Air outlet
flange is placed under the indoor unit.
a
b
a
Installation and operation manual
b
General safety precautions
c
Washers for hanger bracket
d
Screws for duct flanges (M5×12)
e
Hexagon head bolt (M10×40)
f
Attached piping with sealing
g
Tie wrap
h
Spring washer
i
Air outlet flange (under the indoor unit)
Installation and operation manual
12
Measure
Turn OFF all main power
supply switches to the
unit.
Stop operation.
Turn OFF the power
supply.
Notify your installer and
.
report the error code. To
display an error code see
the reference guide of the
user interface.
c
d
e
f
g
h
i
49×
INFORMATION
Refer
to
the
www.daikin.eu
search function
If after checking all above items, it is impossible to fix the problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).
9
Relocation
Contact your dealer to remove and reinstall the entire unit. Moving
units requires technical expertise.
10

Disposal

NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
12

Unit installation

12.1

Preparing the installation site

WARNING
The appliance using R32 refrigerant shall be stored so as
to prevent mechanical damage and in a well-ventilated
room without continuously operating ignition sources (e.g.
open flames, an operating gas appliance, or an operating
electric heater). The room size shall be as specified in the
General safety precaution.
12.1.1
Installation site requirements of the
indoor unit
INFORMATION
The sound pressure level is less than 70 dBA.
CAUTION
Appliance NOT accessible to the general public. Install it in
a secured area, protected from easy access.
This unit is suitable for installation in a commercial, light
industrial, household and residential environment.
WARNING
For units using the R32 refrigerant it is necessary to keep
any required ventilation openings clear of obstructions.
▪ Drainage. Make sure condensation water can be evacuated
properly.
reference
guide
located
on
for more troubleshooting tips. Use the
to find your model.
FDA200+250AXVEB
Split system air conditioners
3P580564-1E – 2022.11
https://

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fda250axveb

Table of Contents