About The Units And Options; Identification; Identification Label: Indoor Unit; About The Indoor Unit - Daikin FXSN112A2VEB Installer And User Manual

Co2 conveni-pack: indoor unit
Table of Contents

Advertisement

14
|

About the units and options

14 About the units and options
In this chapter

14.1 Identification

14.1.1 Identification label: Indoor unit

14.2 About the indoor unit

14.3 System layout

Installer and user reference guide
40
14.1
Identification...........................................................................................................................................................................
14.1.1
Identification label: Indoor unit .............................................................................................................................
14.2
About the indoor unit.............................................................................................................................................................
14.3
System layout..........................................................................................................................................................................
14.4
Combining units and options..................................................................................................................................................
14.4.1
Possible options for the indoor unit ......................................................................................................................
NOTICE
When installing or servicing several units at the same time, make sure NOT to switch
the service panels between different models.
Location
Use the system in the following temperature and humidity ranges for safe and
effective operation.
Outdoor unit
Indoor unit
Indoor humidity
(a)
To avoid condensation and water dripping out of the unit. If the temperature or the
humidity is beyond these conditions, safety devices may be put in action and the air
conditioner may not operate.
INFORMATION
The following illustration is an example and might NOT match your system layout.
Cooling and drying
–5~43°C DB
14~24°C WB
(a)
≤80%
40
40
40
40
41
41
Heating
–20~16°C WB
15~27°C DB
FXSN50~112A2VEB