OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY lay persons. TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE SPECIFICALLY DESIGNED FOR USE WITH THE Sound pressure level is less than 70dB(A).
Selecting installation site Optional accessories There are two types of remote controllers: wired and wireless. (See figure 1 figure Select a remote controller according to customer request and install in an appropriate place. Select an installation site where the following conditions are Refer to catalogues and technical literature for selecting a fulfilled and that meets your customer's approval.
Ceiling opening For other installation than standard installation, contact NOTE Service access panel (optional accessory) your Daikin dealer for details. Air filter Air inlet duct The fan speed for this indoor unit is preset to provide standard Duct service opening external static pressure.
Drain socket (attached to the unit) Drain hose (supplied with the unit) Metal clamp (supplied with the unit) Large sealing pad (supplied with the unit) Drain piping (field supply) Refrigerant piping Wrap the supplied large sealing pad over the metal clamp and drain hose to insulate and fix it with clamps.
Electric wiring work Caution for drain socket Do not remove the drain pipe plug. Water might leak out. General instructions The drain outlet is only used to discharge water if the drain pump is not used or before maintenance. Gently put in and All field wiring and components must be installed by a licensed ...
Specifications for field supplied fuses and wire Do not connect wires of different gauge to the same grounding terminal. Looseness in the connection may deteriorate the protection. Power supply wiring Remote controller cords and wires connecting the units should Model Field fuses Wire Size...
Field setting Precautions A single switch can be used to supply power to units on the Field setting must be made on the remote controller in function of the same system. However, branch switches and branch circuit installation condition. breakers must be selected carefully. Setting can be made by changing the "Mode number", "First ...
Page 12
External static pressure settings If the external static pressure higher than 100 Pa, do Settings for external static pressure can be achieved in 2 ways: not use airflow automatic adjustment function. If there is no change after airflow adjustment in the ...
Test operation Computerised control (forced off and on/off operation) Wire specifications and how to perform wiring Refer to the installation manual of the outdoor unit. Connect input from outside to terminals T1 and T2 of the The operation lamp of the remote controller will flash when an error terminal board (remote controller to transmission wiring).
If chains are present, unhook the chains. Shut the air inlet grille. (Only for bottom suction.) Refer to item no. 1. After turning on the power, press FILTER SIGN RESET button. The "TIME TO CLEAN AIR FILTER" display is turned off. How to clean air outlet and outside panels Clean with soft cloth.