10. Remove the c-clip from the shaft. This is not required for rebuild and can be discarded.
11. Slide the connecting rod removal tool (part # 07-00579-00) behind the connecting rod. Have the angled
edge towards the motor. Rotate the tool so the open slot is parallel to the connecting rod.
12. Remove the connecting rods and piston using a Two Arm Puller and Puller Block.
Installing New Connecting Rods
1. Polish the motor shaft with a wire brush or fine sand paper to aid in installing the new connecting rods.
2. Remove the compressor fan cover on the rear of the air compressor and fan.
3. Place the air compressor on a press using a solid block to support the motor shaft.
4. Insert the key into the shaft and place a lubricant on the shaft. Place the crankshafts on the motor shaft,
aligning the keyway with the crankshaft. Pistons need to be opposite each other and at a 90 degree position
of the base.
5. Insert the gauge tool over the motor shaft and slowly press the press until the gauge is flush with the top of
the motor shaft.
Procedure for Air Compressor Reassembly
1. Remove the air compressor from the press and replace the rear fan and cover.
2. Refer to Air Compressor Minor Rebuild
5.3

Filter Assembly

Refer to Warnings in the beginning of this
The filter assembly
(Figure
moisture will be removed at the water separator. Immediately after the water separator are two particulate filters
that removes solid debris from the air stream. The condensate and any solid material that settles to the bottom of
the filter assembly is blown out of the line when the Water Drain Valve (WDV) opens.
T-374
Procedure for
Service
section before performing maintenance.
5.1) consists of a water separator and two particulate filters. Any of the condensed
Reassembly.