Wiring The Dc Power Source - Cisco IE 1000 Hardware Installation Manual

Industrial ethernet switch
Table of Contents

Advertisement

Switch Installation
Connecting to Power
5.
Insert the other end of the exposed ground wire lead into the earth-ground wire connection on the power converter
terminal block. Note that the position of the power converter may vary on different switch models.
6.
Tighten the earth-ground wire connection terminal block screw.
Note:
Torque to 8 in.-lb, not to exceed 10 in-lb.
Warning:
An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that
no exposed portion of the DC-input power source wire extends from the power and relay connector. Statement 122
7.
Insert the twisted-pair wire leads into the terminal block line and neutral connections. Insert the wire (labeled number
1 in
Figure 6 on page
page
15) lead into the line wire connection. Ensure that only wire with insulation extends from the connectors. See
Figure 6 on page
8.
Tighten the line and neutral terminal block screws.
Note:
Torque to 8 in.-lb, not to exceed 10 in-lb.
9.
Connect the red wire to the positive pole of the DC power source, and connect the black wire to the return pole.
Ensure that each pole has a current-limiting-type fuse rated to 30 Amp.

Wiring the DC Power Source

Read these cautions and warnings before wiring the switch to the DC power source.
Warning:
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022
Warning:
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: 6A.
Statement 1005
Warning:
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning:
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning:
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Caution:
For wire connections to the power and alarm connectors, you must use UL- and CSA-rated, style 1007 or
1569 twisted-pair copper appliance wiring material (AWM) wire (such as Belden part number 9318).
To wire the switch to a DC power source, follow these steps:
1.
Locate the two power connectors on the switch front panel labeled DC-A and DC-B.
Note:
Non-PoE units have only one power connection (DC-A).
2.
Identify the connector positive and return DC power connections. The labels for power connectors DC-A and DC-B
are on the switch panel as displayed below.
Label
Connection
+
Positive DC power connection
Return DC power connection
3.
Measure two strands of twisted-pair copper wire (16-to-18 AWG) long enough to connect to the DC power source.
15) lead into the neutral wire connection and the wire (labeled number 2 in
15.
16
Figure 6 on

Advertisement

Table of Contents
loading

Table of Contents