Power Supply Installation
Figure 57: Inserting the DC-Power Supplyin the Catalyst WS-C3850 Switch
Figure 58: Inserting the DC-Power Supply in the Catalyst WS-C3850-48XS Switch
Step 6
Connect the input power as described in

Wiring the DC Input Power Source

Procedure
Step 1
Using a wire-stripping tool, strip each of the four wires from the DC-input power source to the appropriate
length for the terminals.
Warning
Step 2
Using a Panduit crimping tool, crimp the fork-type terminals to the copper conductor, 90C, 12-AWG DC
power input wires.
Step 3
Connect the DC-input power terminals to the terminal blocks. Make sure to match the polarity (negative to
negative, positive to positive) when connecting the wires to the terminal blocks. Connect the ground wire to
a grounded metal rack or to earth ground if the switch is not in a grounded rack.