Technical Specifications
Technical Specifications
1
Operating temperature
(Measured inside enclosure, 1" below
switch)
Operating humidity
Operating shock
Operating altitude
Storage altitude
Power Requirements
DC input voltage
Power consumption
Physical Dimensions
Weight
Dimensions (W x D x H).8 x 5.3 x 5 in.
3
(45.7 x 134 x 127 mm)
1. Operating temperatures exceeding 60C are not covered by the product safety certifications and approvals. However, the switch can
function in the installations under the environmental conditions listed.
2. When using industrial grade SFP modules, maximum operating temperature limits shown in table 1 apply. When using commercial
grade SFP modules, maximum system operating temperature limits must be de-rated by 15 deg. C.
3. Width includes the cosmetic end-caps. Height does not include the power and alarm connections.
POE
-34C to +74C
• -40C to +70C (40 lfm Vented
Enclosure Operating)
• -40C to +60C (Sealed Enclosure
Operating)
• -34C to +74C (Minimum 200 lfm
Fan or Blower equipped Enclosure
Operating)
-40C to +85C (Type Tested to +85C for
2
16 hours)
5 to 95% (noncondensing)
30 g at 11 ms, and 200 g at 2.11 ms.
Up to 13,000 ft (3962 m)
Up to 40,000 ft (12,192 m)
• Marked range:
– 12-24 VDC (IE1000-4T1T / IE1000-6T2T)
– 48-54 VDC (IE1000-4P2S / IE1000-8P2S)
• Maximum operating range:
– 9-32 VDC (IE1000-4T1T / IE1000-6T2T)
– 48-54 VDC (IE1000-4P2S / IE1000-8P2S)
Note:
• The DC-input power supply is an SELV circuit, and it can only be connected to
another SELV circuit.
• IE-1000-4T1T-LM -- 3.6W
• IE-1000-6T2T-LM -- 4.8W
• IE-1000-4P2S-LM -- 140.4W
• IE-1000-8P2S-LM -- 205.2W
IE-1000-4T1T-LM --
1.10 lb (0.50 kg)
IE-1000-6T2T-LM -- 1.25 lb (0.57 kg)
IE-1000-4P2S-LM -- 1.70 lb (0.77 kg)
IE-1000-8P2S-LM -- 1.85 lb (0.84 kg)
IE-1000-4T1T-LM -- 1.5
x 4.5 x 5 in. (38.1 x 115 x 127 mm)
IE-1000-6T2T-LM -- 1.8 x 4.5 x 5 in. (45.7 x 115 x 127 mm)
IE-1000-4P2S-LM -- 1.8 x 5.3 x 5 in. (45.7 x 134 x 127 mm)
IE-1000-8P2S-LM -- 1
46
Non-POE
-16C to +74C
• -20C to +70C (40 lfm Vented
Enclosure Operating)
• -20C to +60C (Sealed Enclosure
Operating)
• -16C to +74C (Minimum 200 lfm
Fan or Blower equipped Enclosure
Operating)
85C Type Tested for 16 hours