USER'S MANUAL
Rev. 02/2022
015
CD Automation S.r.l.
Via Picasso, 34/36 - 20025 Legnano (MI)- Italy
Tel. +39 0331 577479 - Fax +39 0331 579479
E-mail: info@cdautomation.com - Web: www.cdautomation.com
3PH
690V
from 60A to 800A
M-RC3-60-800-690V

Advertisement

Table of Contents
loading

Summary of Contents for CD Automation REVO C 3PH 690V

  • Page 1 USER’S MANUAL 690V Rev. 02/2022 from 60A to 800A M-RC3-60-800-690V CD Automation S.r.l. Via Picasso, 34/36 - 20025 Legnano (MI)- Italy Tel. +39 0331 577479 - Fax +39 0331 579479 E-mail: info@cdautomation.com - Web: www.cdautomation.com...
  • Page 3: Declaration Of Conformity

    P.I. 08925720156 -Tel. +39 0331 577479 - Fax +39 0331 579479 E-mail: info@cdautomation.com - Web: www.cdautomation.com Declare that the product / Dichiara che il prodotto: Revo C 3Ph 690V 60-800A PRODUCT DESCRIPTION: Electric power control SCOPE OF APPLICATION: Thermal control process DESCRIZIONE DEL PRODOTTO: Unità...
  • Page 4: Important Warnings For Safety

    User’s manual REVO C 3PH from 60A to 800A - 690V Important warnings for safety This chapter contains important information for the safety. The not observance of these instructions may result in serious personal injury or death and can cause serious damages to the Thyristor unit and to the components system included.
  • Page 5 User’s manual REVO C 3PH from 60A to 800A - 690V WARNING! All service including inspection, installation, wiring, maintenance, troubleshooting, fuse or other user serviceable component replacement must be performed only by properly qualified personnel. Service personnel must read this manual before proceeding with work. While service is being performed unqualified personnel should not work on the unit or be allowed in the immediate vicinity.
  • Page 6 User’s manual REVO C 3PH from 60A to 800A - 690V AVERTISSEMENT! Au moment de relever des mesures de tension ou de courant en direct, utiliser un équipement de protection individuelle approprié pour les tensions et les potentiels d’arc électrique concernés.
  • Page 7: Maintenance

    User’s manual REVO C 3PH from 60A to 800A - 690V Maintenance In order to have a corrected cooling, the user must clean the heat-sink and the protective grill of the fans. The frequency of this servicing depends on environmental pollution. Also check periodically if the screw for the power cables and safety earth are tightened correctly (See Connection Diagram).
  • Page 8: Table Of Contents

    User’s manual REVO C 3PH from 60A to 800A - 690V Summary Declaration of conformity....... . .3 Important warnings for safety .
  • Page 9 User’s manual REVO C 3PH from 60A to 800A - 690V 10.4 How to........... 51 10.5 Using the Configurator .
  • Page 10: Introduction

    User’s manual REVO C 3PH from 60A to 800A - 690V Introduction A thyristor unit is semiconductor device which acts as a switch formed by two thyristors in ant parallel.To switch on the alternating current the input signal will be on and the thyristor will switch off at first Zero Crossing voltage with no input signal.
  • Page 11: Advantages Compared With Analog Thyristor Unit

    User’s manual REVO C 3PH from 60A to 800A - 690V Advantages compared with analog thyristor unit Communication RS485 is a standard feature of REVO C this allows the use of many information like: current, power, load state and all the parameters for diagnostic and configuration. Ulterior advantages of the digital system vs the analogical is the flexibility and the possibility of implement special characteristics without change the hardware.
  • Page 12: Software Configurator

    User’s manual REVO C 3PH from 60A to 800A - 690V Software Configurator Thyristor configurator software is free and is possible download it from our site. If the Order Code is in line with requirement, then unit has been already configured in Factory and it’s ready to use.
  • Page 13: Quick Start

    User’s manual REVO C 3PH from 60A to 800A - 690V Quick Start Attention: this procedure must be carried out by skilled people only. If your REVO C code is in line with what you really need, then the main configuration is already done by Producer and you just need to do the following steps: Verify REVO C current sizing.
  • Page 14: Basic Connections And Sizing

    User’s manual REVO C 3PH from 60A to 800A - 690V Basic Connections and sizing Star wiring with resistive load (control on three phases with REVO C-3PH) 1,73V V = Nominal voltage of the load I = Nominal current of the load P = Nominal power of the load Star wiring with resistive load + Neutral (control on three phases with REVO C-3PH) 1,73V...
  • Page 15: Identification And Order Code

    User’s manual REVO C 3PH from 60A to 800A - 690V Identification and Order Code 5.1 Identification of the unit Caution: Before to install, make sure that the Thyristor unit have not damages. If the product has a fault, please contact the dealer from which you purchased the product. The identification’s label give all the information regarding the factory settings of the Thyristor unit, this label is on the unit, like represented in figure.
  • Page 16: Order Code

    User’s manual REVO C 3PH from 60A to 800A - 690V 5.2 Order Code REVO C 3PH CURRENT FUSES CONTROL MODE description description code note description code note Fixed Fuses Included 0 6 0 Open Loop Fixed Fuses Included 0 9 0 Voltage 120A Fixed Fuses Included...
  • Page 17 SCR (relay output). Option that allows communication with a smart WiFi phone. From your smart phone via the CD Automation App, direct to your thyristor unit in the cabinet to read current, voltage, power and energy totalization as well as the ability to change parameters to improve process and product quality without opening the cabinet door.
  • Page 18: Technical Specifications

    User’s manual REVO C 3PH from 60A to 800A - 690V Technical Specifications 6.1 General features Operative voltage: 690V +5% max -10% min Cover and Socket material: PolymericV2 Utilization Category: AC-51 AC-55b IP Code: Method of Connecting: Load in Delta, Load in Star Auxiliary voltage: Order code RC3_ _ _ -_1 = line voltage 100/120V transformer range 90:135V (8 VA Max) Order code RC3_ _ _ -_2 = line voltage 200/208/220/230/240V transformer range 180:265V (8 VA Max)
  • Page 19: Fan Specification

    User’s manual REVO C 3PH from 60A to 800A - 690V 6.4 Fan Specification Number of fans Number of fans Number of fans Size 230Vac - Standard 115Vac - Option 24Vdc - Option 60A,90A One Fan - 16W One Fan - 14W One Fan - 7W 120A,150A,180A,210A Two Fans - (16W x 2) 32W...
  • Page 20: Wi-Fi Transmitter Module

    User’s manual REVO C 3PH from 60A to 800A - 690V 6.8 Wi-Fi Transmitter Module Models RC_ _ _-_ _ _ _ _-_ _ _ with WiFi option contains a Wi-Fi transmitter module, see model label plate for details on which module is installed. The transmitter module is mounted on the top of the microprocessor board.
  • Page 21: Installation

    User’s manual REVO C 3PH from 60A to 800A - 690V Installation AIR FLOW OUT (V) Before to install, make sure that the Thyristor unit have not damages. If the product has a fault, please contact the dealer from which you purchased the product.
  • Page 22: Dimensions And Weight

    User’s manual REVO C 3PH from 60A to 800A - 690V 7.1 Dimensions and weight REVO-C 3PH REVO-C 3PH 60A÷90A (S11) 120A÷210A (S13) W 137mm - H 440mm - D 270mm W 262mm - H 440mm - D 270mm Weight 10,5 Kg Weight 18 Kg REVO-C 3PH REVO-C 3PH...
  • Page 23: Fixing Holes

    User’s manual REVO C 3PH from 60A to 800A - 690V 7.2 Fixing holes REVO-C 3PH REVO-C 3PH 60A÷90A (S11) 120A÷210A (S13) REVO-C 3PH REVO-C 3PH 300A÷500A (S14) 600A÷800A (S17)
  • Page 24: Wiring Instructions

    User’s manual REVO C 3PH from 60A to 800A - 690V Wiring instructions The Thyristor unit could be susceptible to interferences lost by near equipments or by the power supply, for this reason in accord to the fundamental practices rules is opportune take some precautions: The coil contactor, the relays and other inductive loads must be equipped with opportune RC filter.
  • Page 25: Cable Dimensions (Suggested) Of Earth And Of The Command Terminals

    User’s manual REVO C 3PH from 60A to 800A - 690V 8.3 Cable dimensions (suggested) of Earth and of the Command Terminals Earth Command Terminals Cable Cable Current Screw mm² mm² 60A (S11) 0,50 90A (S11) 0,50 120A (S13) 0,50 150A (S13) 0,50 180A (S13)
  • Page 26: Terminals Positions

    User’s manual REVO C 3PH from 60A to 800A - 690V 8.4 Terminals Positions Size S13 / S14 Open and flip the cover Size S11 / S17...
  • Page 27: Power Terminals

    User’s manual REVO C 3PH from 60A to 800A - 690V REVO-C 3PH 8.5 Power Terminals 60-90A (S11) Warning: Before connecting or disconnecting the unit check that power and control cables are isolated from voltage sources. Terminal Description Line Input Phase 1 Line Input Phase 2 Line Input Phase 3 Load Output Phase 1...
  • Page 28 User’s manual REVO C 3PH from 60A to 800A - 690V 8.5.1 Bar dimensions S14 (300-500A) 3PH from 300 to 400A To other screw To other 3PH from 450 to 500A screw Current 300A (S14) 71mm 60mm 45mm 57mm 30mm 350mm 174mm 400A (S14)
  • Page 29: Control Terminals

    User’s manual REVO C 3PH from 60A to 800A - 690V 8.6 Control Terminals Warning: Before connecting or disconnecting the unit check that power and control cables are isolated from voltage sources. Terminal Block M1 Terminal Description NO - Normally Open contact alarm relay output (Thermal or SC/HB) C - Common contact alarm relay output NC - Normally Close contact alarm relay output (Thermal or SC/HB) + Analog Input2 (0-10Vdc/4-20mA Reference/ext.feedback)
  • Page 30: Schematic

    User’s manual REVO C 3PH from 60A to 800A - 690V 8.7 Schematic Caution: this procedure must be performed only by qualified persons. Option Ethernet Profibus Branch circuit protection Fuse 1A Max Micro USB +24V GND 15 16 Power Microprocessor +24Vdc Retransmit Second...
  • Page 31 User’s manual REVO C 3PH from 60A to 800A - 690V Caution: this procedure must be performed only by qualified persons. Indicative connection diagrams. Refer to local regulations for proper system protection. Option Second Ethernet Profibus Serial RS485 Branch Circuit Protection Fuse 1A Max...
  • Page 32 User’s manual REVO C 3PH from 60A to 800A - 690V 8.7.1 SSR Control Input schematic For SSR input use follow the schematic below and configure Digital Input 1 as Fast Enable. Analog Input 1 INPUT * SSR Input: 4÷30Vdc 5mA Max (ON >4Vdc / OFF <1Vdc) Frequency 3Hz Max - On time min.
  • Page 33: Connection Diagram For 3 Phases

    User’s manual REVO C 3PH from 60A to 800A - 690V 8.8 Connection Diagram for 3 phases Caution: this procedure must be performed only by qualified persons. Relay Thermal or SC/HB Analog Inp.2 0-10VDC /4-20mA Reference Ext.FeedBack Analog Inp.1 0-10VDC /4-20mA ANALOG SET POINT Fan Power Supply See Order Code for the value...
  • Page 34: Control Panel

    User’s manual REVO C 3PH from 60A to 800A - 690V Control Panel The Control Panel is placed on the front of the thyristor unit, on his display you can visualize the alarms, the input and output signals and all the configuration parameters. Iout0.0A Vout0.0V Pout0%...
  • Page 35: Menu Navigation

    User’s manual REVO C 3PH from 60A to 800A - 690V 9.1 Menu navigation The menus are accessible using the control panel keypad and display. Choose Enter Choose Edit HOME PAGE Menu Password Parameter Parameter Iout0.0A Password Set Point Iout0.0A 100% SP 100% Iout0.0A...
  • Page 36: Control Panel Led

    User’s manual REVO C 3PH from 60A to 800A - 690V 9.2 Control Panel Led The four indicators on the control panel show the general state of the power controller. Flashing Power output set locally or via communications Local/Remote Power output set remotely (via analog input) Aux High Output enabled SP 100%...
  • Page 37: Parameter List

    User’s manual REVO C 3PH from 60A to 800A - 690V 9.4 Parameter list This chapter describes the parameter on the menus accessed via the control panel and Configurator software. To learn how to access the menus described below see “Menu navigation” chapter. Menu Listing The table below lists the parameters found on each menu.
  • Page 38 User’s manual REVO C 3PH from 60A to 800A - 690V 9.4.1 Operator Menu This section describes each item on the operator menu. Use this menu to view the measured values and basic settings of the power controller. The password to access this menu is 0. Modbus Par.
  • Page 39 User’s manual REVO C 3PH from 60A to 800A - 690V 9.4.2 Setup Menu This section describes each item on the setup menu. Use this menu to configure the power controller for the load. The password to access this menu is 2. Modbus Par.
  • Page 40 User’s manual REVO C 3PH from 60A to 800A - 690V 9.4.3 Advanced Setup Menu This section describes each item on the advanced setup menu. Use this menu to configure the power switching, closed loop control of power and adjustable settings for data logging and heater bakeout. The password to access this menu is 10.
  • Page 41 User’s manual REVO C 3PH from 60A to 800A - 690V Modbus Par. Parameter Name Description Default Range Address Type Feedback Read Choose the feed-back type Write Option Description Value V² Voltage squared None No feed-back I² Current squared Voltage Voltage Current Current...
  • Page 42 User’s manual REVO C 3PH from 60A to 800A - 690V Modbus Par. Parameter Name Description Default Range Address Type Set a delay between when the resistance HB Delay drops below the value set for a heater 0 to 255 Read break sensitivity and when the heater break (0 to 12,75...
  • Page 43 User’s manual REVO C 3PH from 60A to 800A - 690V 9.4.4 Hardware Menu This section describes each item on the hardware menu. Use this menu to configure how the inputs and outputs are used in the application. The password to access this menu is 5. Modbus Par.
  • Page 44 User’s manual REVO C 3PH from 60A to 800A - 690V Modbus Par. Parameter Name Description Default Address Type DI1 Functn Choose how the signal detected by digital input 1 Read is used Write Option Description Value Enable Enable power output V Feedback Use voltage feed-back when on Local / Rmt...
  • Page 45 User’s manual REVO C 3PH from 60A to 800A - 690V Modbus Par. Parameter Name Description Default Address Type Choose for which conditions the digital output Alm Out Fn indicates alarm. The output always indicate an alarm when the heat sink is over temperature. The digital output is energized for normal operating condition and de-energized when the power Read...
  • Page 46 User’s manual REVO C 3PH from 60A to 800A - 690V Modbus Par. Parameter Name Description Default Range Address Type value retransmitted Rtx Scale parameter represented Read 0 to 9999 the full scale of the analog output. Write See the table below Recommended Resulting Signal Resulting Signal...
  • Page 47 User’s manual REVO C 3PH from 60A to 800A - 690V 9.4.5 Communication Menu This section describes each item on the communication menu. Use this menu to configure the communication options. The password to access this menu is 3. Modbus Par.
  • Page 48 User’s manual REVO C 3PH from 60A to 800A - 690V Modbus Par. Parameter Name Description Default Range Unit Address Type Set the amount of time to wait for WD Reset Read communication message before 0 to 255 Write triggering the watchdog error Wi-Fi Addr Indicate the IP address of the WiFi 94-95...
  • Page 49 User’s manual REVO C 3PH from 60A to 800A - 690V 9.4.6 Monitoring Menu This section describes each item on the monitoring menu. Use this menu to view the states of digital input, values of analog input and information about the power controller such as serial number and software version. The password to access this menu is 0.
  • Page 50 User’s manual REVO C 3PH from 60A to 800A - 690V Modbus Par. Parameter Name Description Range Unit Address Type Analog In1 Indicates the percent of full scale measured Read 0 to 100.0 by analog input 1 Only Analog In2 Indicates the percent of full scale measured Read 0 to 100.0...
  • Page 51: Using The Configurator

    User’s manual REVO C 3PH from 60A to 800A - 690V Using the Configurator Confi gurator software can be used like an alternative of the power controller’s keypad and set the advanced features not available via the power controller’s onboard user interface. Here we explain how to use it.
  • Page 52 User’s manual REVO C 3PH from 60A to 800A - 690V Procedure to communicate with a power controller: 1) if used direct USB connection: - Connect the USB cable between the computer and the micro USB connector on the power controller’s keypad - if necessary, wait for the USB driver to install.
  • Page 53: Using The Configurator

    User’s manual REVO C 3PH from 60A to 800A - 690V 10.5 Using the Confi gurator After software has been installed, communication has been set up and model type selected, is possible operate with power controller. 10.5.1 To view or save a power controller’s settings using “Simple”...
  • Page 54 User’s manual REVO C 3PH from 60A to 800A - 690V 10.5.3 To download a recipe fi le into a power controller: 1) Click Simple, if not already on the Simple view 2) Click existing recipe Open 3) Locate and select the recipe fi le and click Open 4) Click 5) Click...
  • Page 55 User’s manual REVO C 3PH from 60A to 800A - 690V 10.5.8 To reset the power totals: 1) Click Test, if not already on the test view 2) Click Online 3) Click Reset Totals 4) Click 10.5.9 Setting Up and Using Data Logging To set up data logging: 1) Click Test, if not already on the test view 2) Click...
  • Page 56: Software General Information

    User’s manual REVO C 3PH from 60A to 800A - 690V 10.5.10 To retrieve a data log fi le from the power controller: 1) Click Test, if not already on the test view 2) Click Online 3) Click Load Analyzer 4) Click Connect 5) Select a fi le from the list...
  • Page 57 User’s manual REVO C 3PH from 60A to 800A - 690V 10.6.2 Simple Section This section is used to create, save, upload and download recipes of parameters settings. Can be used also to see the settings in a controller. Simple page is the default page when select the model using the Model Button, but If not selected is possible access it clicking the Simple tab below the main menu.
  • Page 58 User’s manual REVO C 3PH from 60A to 800A - 690V 10.6.3 Test Section This section is used to monitor and adjust the operation of the power controller in real time using RS485 or USB communication port. After select the model, is possible access to this section clicking the “TEST”...
  • Page 59 User’s manual REVO C 3PH from 60A to 800A - 690V Buttons setup options: Firing: view and set the fi ring type and the associated parameters Feedback: view and set feedback type Communication: view and set communication options for ports, protocols and fi eldbus Confi gure and monitor the analog inputs: 1: click Ai 1 to view the signal type...
  • Page 60 User’s manual REVO C 3PH from 60A to 800A - 690V 10.6.4. Load Analyzer Load Analyzer is used for monitoring values graphically represent Click on Load Analyzer button on the test page will open Load Analyzer window. Is possible see 3 channels (Ch 1, Ch 2 and Ch 3). For each channel confi gure a pen on the graph: On/Off...
  • Page 61 User’s manual REVO C 3PH from 60A to 800A - 690V 10.6.5 Data Log Window In the power controller the data log window is used to manage fi les and set up logging parameter like log interval time and date/time in rtc slider: Enable and disable data logging function.
  • Page 62 User’s manual REVO C 3PH from 60A to 800A - 690V 10.6.7 MSG view Message view display the communication activity between the computer and the power controller. PORT COM: use this view to see when the COM port is accessed and its settings MODBUS: Modbus communication protocol area Area: use this view to see parameters READ...
  • Page 63: Configurable Inputs And Outputs

    User’s manual REVO C 3PH from 60A to 800A - 690V Configurable Inputs and Outputs The REVO C power controller features two digital inputs, up to two analog inputs and a relay output. Some models also include an analog output for retransmitting a measured value to other automation equipment. This section describes the various functions of these inputs and outputs and how they interact with other features of the power controller.
  • Page 64: Analog Input 2: Set Point, Feedback Or Current Limit Set Point

    User’s manual REVO C 3PH from 60A to 800A - 690V 11.3 Analog Input 2: Set Point, Feedback or Current Limit Set Point What this input does is user-configurable. Connect an analog signal that indicates: • An alternate set point signal •...
  • Page 65: Alarm Description

    User’s manual REVO C 3PH from 60A to 800A - 690V Alarm description 12.1 Heater Break Alarm This option allows you to diagnose any load breakage. The diagnostics is based on the comparison of the value of the nominal resistance of the load with respect to the resistance measured in real time. The nominal resistance is calculated using the Operative Load Voltage (Nom Line V) and Nominal Current of the load (Nominal I) parameters.
  • Page 66: Aux High

    User’s manual REVO C 3PH from 60A to 800A - 690V 12.2. AUX High This alarm is displayed when the auxiliary supply voltage exceeds the established ranges. If the alarm situation persists for more than 5 seconds, the unit will go into protection. 12.3 AUX Low This alarm is displayed when the auxiliary supply voltage is lower than the established ranges.
  • Page 67: 13 "Enable" Function In Static Unit

    User’s manual REVO C 3PH from 60A to 800A - 690V “Enable” Function in static Unit The “Enable” function can work in several ways • from Digital input • from Serial Port • from Digital Input + Serial Port • from FieldBus •...
  • Page 68: Using Serial Port Rs485 Only

    User’s manual REVO C 3PH from 60A to 800A - 690V 13.2 Using Serial Port RS485 only The static unit has an RS485 Modbus RTU serial port always present. By setting the Digital Input as “Not Used” or different from “Enable” it is possible to control the enable from serial port with bit 2 of parameter 14 If bit 2 = 1: Enabled If bit 2 = 0: Disabled...
  • Page 69: Using Fieldbus Only

    User’s manual REVO C 3PH from 60A to 800A - 690V 13.4 Using FieldBus only The static unit as an option can be ordered with a FieldBus (Ex: profinet). This option continuously writes the values on the unit keeping them up to date. Using the field bus it is possible to change the status of the Sw contact with bit 2 of the “Command table”...
  • Page 70: Using Digital Input + Fieldbus

    User’s manual REVO C 3PH from 60A to 800A - 690V 13.5 Using Digital Input + FieldBus The static unit as an option can be ordered with a FieldBus (Ex: profinet). This option continuously writes the values on the unit keeping them up to date. The external contact Sw and the internal software contact Sw are connected in series, therefore if you want...
  • Page 71: Firing Type

    User’s manual REVO C 3PH from 60A to 800A - 690V Firing type Choose a correct firing type allows to optimize the thyristor unit for the installed load. The firing type has already configured in line with customer requirements that are defined in the Order Code. The Order Code is written on the identification label.
  • Page 72: Soft Start With Burst Firing

    User’s manual REVO C 3PH from 60A to 800A - 690V 14.4 Soft Start with Burst Firing This is an additional function to the Burst Firing. The unit start in phase angle mode with a ramp starting from Voltage Supply (V) zero up to the full tension in the cycles number set in the parameter.
  • Page 73: Delay Triggering With Burst Firing

    User’s manual REVO C 3PH from 60A to 800A - 690V 14.7 Delay Triggering with Burst Firing The Delay Triggering firing is used Without Delay Triggering With Delay Triggering the control a primary of transformer coupled with normal resistances on the secondary (N.B. Transient over-current don’t connect cold resistances on Delay angle...
  • Page 74: Current Limit

    User’s manual REVO C 3PH from 60A to 800A - 690V Current Limit The Current Limit is available on REVO C with Phase Angle firing mode only. It control the firing angle of the thyristor to maintain the three RMS current under the set value. When the current exceeds this value, the voltage is decreased up to reach the current limit set.
  • Page 75: Current Limit Tuning Procedure

    User’s manual REVO C 3PH from 60A to 800A - 690V 15.2 Current Limit tuning procedure • Give the power supply and set the current limit to zero: - In analog mode, set the analog input 2 to zero - In digital mode, set the parameter=0 •...
  • Page 76: Heater Bakeout Function

    User’s manual REVO C 3PH from 60A to 800A - 690V Heater bakeout function When a heater insulated with magnesium oxide (MgO) is powered off, not in use or in storage for a long period of time, it can absorb moisture. If full power is applied, excessive current can damage the heater or blow fuses. The heater bakeout feature limits the voltage and current applied as the heater is brought back in to service.
  • Page 77: Control Mode (Feed-Back)

    User’s manual REVO C 3PH from 60A to 800A - 690V Control Mode (feed-back) The Control Mode (feed-back) type has already configured in line with customer requirements that are defined in the Order Code. The Order Code is written on the identification label. However, if you wish to change the Control Mode (feed-back) type you can use the software configurator or the Control Panel.
  • Page 78: Supply The Electronic Board

    User’s manual REVO C 3PH from 60A to 800A - 690V Supply the electronic board The REVO C thyristor unit, to work, requires a voltage supply for the electronic boards. The Max consumption is 8VA. The voltage supply for the electronic boards is configured in line with customer requirements that are defined in the Order Code.
  • Page 79: 24Vdc Input Auxiliary Supplemental Power

    User’s manual REVO C 3PH from 60A to 800A - 690V 24Vdc input Auxiliary supplemental power The 24Vdc Auxiliary Supply input in Terminal Block M2, terminals 1 and 4, can be used as an auxiliary power supply when the main network fails. This auxiliary power supply keeps the communication circuits powered allowing data to be transferred to the supervision system.
  • Page 80: Rs485 Serial Port

    User’s manual REVO C 3PH from 60A to 800A - 690V RS485 Serial port The serial communication port RS485 is available on the Command Terminals. On this port may be done a network up to 127 REVO C. Terminal M1 Description RS485 A RS485 B...
  • Page 81: Fieldbus Communication Option

    User’s manual REVO C 3PH from 60A to 800A - 690V Fieldbus communication option Other serial communication port are available as option, see Communication Manual for details. Size S11: Size S13: 120-210A 690V Size S17: 600-800A 690V 60-90A 690V Size S14: 300-500A 690V Caution: If Bus port is not connected or in error, all writable parameters are set to value...
  • Page 82: Internal Fuse

    User’s manual REVO C 3PH from 60A to 800A - 690V Internal Fuse The thyristor unit have internal fuse extrarapid at low I t for the thyristor protection of against the short-circuits. The Fuses must have I²t 20% less than thyristor’s I t.
  • Page 83 CD Automation S.r.l. Via Picasso, 34/36 - 20025 Legnano (MI)- Italy Tel. +39 0331 577479 - Fax +39 0331 579479 E-mail: info@cdautomation.com - Web: www.cdautomation.com...