Enable Chrono; Easy Setup; Status; User Menu - Extraflame HP15 EVO User Manual

Pellet boilers
Table of Contents

Advertisement

• ENABLE CHRONO

it allows to enable/disable the chrono and the various time slots of the boiler.

EASY SETUP

The volumetric weight of the pellet is the ratio between the
weight and the volume of the pellet. This ratio can change while
maintaining the quality of the pellet. By using the eAsy seTup
function, it is possible to change the calibration of the volumetric
weight, increasing or decreasing the pre-set values.
within the stove programs are available the values ranging from "– 3"
to "+ 3"; all the stoves are calibrated at the factory with the optimal
value, which is 0.
If you notice an excessive deposit on the burner pot, enter the EASY SETUP program and lower the value by one unit to "- 1"; then wait for the
following day and if there is no improvement, lower the value again up to a maximum of "- 3". instead, should it be necessary to increase the
calibration of the volumetric weight of the pellet, it is advisable to go from the default value "0" to "+ 1, + 2, + 3" as required.
eXcessive deposiT of pelleTs in The burning poT
-3
-2
ThirD
seconD
DecreAsing
DecreAsing
rAnge if The
rAnge if The
firsT Two Are
firsT is noT
noT enough
enough
n.b.: if these calibrations do not solve the problem, please contact your local customer service centre.

STATUS

USER MENU

The user Menu allows you to:
� set date and time (see chapter before ignition)
� set the programming chrono
� set the LAnguAge
� set the DispLAy
� use the reseT
24
normal operaTion
-1
firsT
DecreAsing
opTiMAL DefAuLT
rAnge (TesT for
vALue
1 DAy)
References reserved to the technician
ENGLISH
liTTle deposiT of pelleTs in The burning poT
0
+1
firsT
increAsing
rAnge
+2
+3
seconD
ThirD
increAsing
increAsing
rAnge if The
rAnge if The
firsT is noT
firsT Two Are
enough
noT enough

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp22 evoHp30 evo

Table of Contents